Before Operating in the Field

NOTE: Make sure machine is properly prepared for field operation. Check the following items before operating:

CAUTION: Do not turn on the machine until you are sure nobody is in the danger zone.

  • All maintenance has been performed.
  • Correct nozzle tips are installed and set for desired spray pattern and row spacing. (See Wet System section for proper nozzle tip and row spacing selection.)
  • Wheel tread width is adjusted for row spacing. (See Setting Tread Width (Without Hydraulic Tread Adjust Option) and Setting Tread Width (With Hydraulic Tread Adjust Option) in the Chassis section.)
  • SprayStar display has been correctly programmed with the following: (See SprayStar System section to program information properly.)
    • Application Rates
    • Tank Volume
    • Minimum Spray Pressure
    • Spray Off Pressure
    • Number of Boom Sections
    • Nozzle Spacing
    • Spray Width
    • Check Flowmeter Calibration Number
    • Calibrate Pressure Sensor
    • Calibrate Wheel Speed Sensor
    • Calibrate Radar Sensor (if equipped)
  • Perform the Boom Air Bleed Process in Recommendations For Eliminating Air from Solution System in the Wet system section.
  • Solution tank is filled, solution valves are correctly positioned and agitation valve (if necessary) is open. (See Wet System section.)
  • Operator is familiar with all machine controls, their functions, and safe operations. (See Chassis and Safety sections.)
  • Clean water tank is filled with clean water. (See Clean Water Tank in the Wet System section.)

OUO6092,000036A-19-20100507