Checking Moistener Column Position

N66184-UN-27MAY04
A - Moistener Pad
B - Spindle Dust Collar
Position of moistener column should be set so first fin of moistener
pad (A) just touches front edge of spindle dust collar (B) as the
spindle exits moistener pad. Top and bottom moistener pads should
be set the same.
IMPORTANT: Moistener pads have been factory installed with fins
perpendicular to spindle as shown. Excessive wear to spindle and spindle
bushings can result if moistener pads are installed with fins parallel
to spindle.
NOTE: Edge of moistener pad should not move more than one-half
way up dust collar at point of farthest penetration of spindle.
|
|
DP99999,00003E0-19-20120208
|
|