Checking Doffer Column Adjustments
A properly positioned doffer column has the following features:
-
Doffer pads parallel to top of spindles when spindles are fully
under pads.
-
Upper housing positioned so doffer pads DO NOT gouge top spindle
nuts and collars.
-
Spindles lightly touch doffer pads as they enter, and clear
as they leave.
Check doffer column height to make sure doffer pads lightly
touch spindles at leading edge of pad.
|
|
DP99999,0000405-19-20090617
|
|