Clean Fill Strainer—As Required

N99947
N99947-UN-11JUL13

A - Quik-Fill Valve

B - Cap


CAUTION: Spray system can contain hazardous material which can cause serious injury or death to you or others. Wear protective clothing, eyewear, and gloves. Drain solution and clean strainer in an area where people, animals, vegetation, and water supply etc., cannot be contaminated.

Quik-Fill valve (A) can contain hazardous materials which can poison causing serious injury or death to you or others. Before removing Quik-Fill cap (B), make sure that Quik-Fill valve is turned off.

  1. Verify Quik-Fill valve (A) is closed.

  2. Open lock levers and remove cap (B).

  3. CAUTION: Do not drain solution onto the ground. Drain into a container. Drain solution in an area where people, animals, vegetation, and water supply, etc., cannot be contaminated.

    Open Quik-Fill valve and drain solution into a suitable container.

  4. After solution has drained, close Quik-Fill valve and replace cap.

  5. N105932
    N105932-UN-10SEP13

    N105933
    N105933-UN-04SEP13

    A - End Cap

    B - Strainer Body

    C - Ring

    D - Strainer

    Remove end cap (A) from end of strainer body (B) and drain solution into suitable container.

    NOTE: Do NOT remove ring (C) from strainer body. Strainer can be removed through end cap opening.



  6. Pull strainer (C) out of strainer body.

  7. Empty strainer and rinse with clean water.

  8. Insert strainer into strainer body.

  9. NOTE: Verify strainer properly seated in the strainer body before cap installed. If strainer not fully seated, cap and O-ring may not seat properly allowing leaks to occur.

    Install cap on strainer body.

  10. Tighten cap and check for leaks.

CS12167,00003FD-19-20130829