Every 500 Hours

1. Replace primary air filter insert.
2. Service fuel tank.

  • Drain water and sediments.
  • Clean suction strainer.

3. Move elevator slats over to next link (one link over).
4. Check coolant and add additive if necessary.
5. Replace bypass oil filter if oil of type Standard Oil is used.

AG,T803584,100 -19-24APR07-1/1