Using Battery Charger

Specific Gravity to 27°C (80°F) Load Status Open Circuit Voltage
1.260-1.280 100% 12,6 +
1.230-1.250 75% 12,4
1.200-1.220 50% 12,2
1.179-1.190 25% 12,0
1.110-1.130 Discharged 11,7

 

A battery charger may be used as a booster to start engine.

Do not use battery charger as a booster if a battery has a specific gravity below 1.150.

Disconnect battery ground before you charge batteries in the machine to prevent damage to electrical components.