Manual Adjustment of Calibration Factor

Screen: SETUP - STANDARD CAL

Press: SETUP >> HARVEST MONITOR >> YIELD CALIBRATION >> STANDARD CALIBRATION

NOTE: If scale weight is more than 50% higher or lower than displayed weight, system will not allow entry of scale weight. It is recommended that you review harvesting procedures and verify vehicle hauling cotton away from picker is also following correct procedures. At that time, repeat calibration procedures.

A new calibration factor can also be entered manually. To calculate calibration factor, divide weight shown on display by new weight on scale ticket. Multiply result by displayed calibration factor (see example below). This is the new calibration factor.

To manually enter a calibration factor:

1. Press CALIBRATION FACTOR button to change calibration factor.

2. Using numeric keypad, input calibration factor.

3. Press CALIBRATION FACTOR button to enter new value.

PC8235

OUO6050,00007AC -19-22JUN04-1/2


PC8234

Example:

Displayed Calibration Factor = 800

800 is the factory default value for the calibration factor.

Weight of cotton shown on display = 5125

New weight of grain from scale ticket = 4830

New Calibration Factor = 754

OUO6050,00007AC -19-22JUN04-2/2