It is recommended that the receiver be, at minimum, 9.1 m (30 ft) away from the tower to prevent both Shading and Multipathing. This distance may vary depending on the frame design of the tower or structure that you are mounting it around.

When using the 91 m (300 ft) extension harness, do not cut the harness to the length needed. This harness has built in voltage protection and is shielded. Cutting the harness will limit the effectiveness of the harness and will cause failures of either the radio or the receiver due to static electricity build up on the harness. This harness was built to be buried underground, so it is suggested to bury all extra harness underground to protect the harness.

After deciding what structure that you will be mounting your base station on, there are five different ways to set up your base station.

  • Utilizing Both The 91 m (300 ft) RTK Extension Harness And Low Loss Coax Cable
  • Utilizing The RTK Extension Harness
  • Utilizing A Repeater
  • Utilizing Just Low Loss Coax Cable
  • Leaving The Radio And Receiver As A Single Unit