External Valve Operation
External valve is used in conjunction with machines that do
not have compatibility with Application Controller 1100 to control
hydraulics of machine. For example, non John Deere machines that are
equipped with John Deere guidance systems and an ISO connector. Ensure
correct external valve is used in conjunction with hydraulic system
of machine. For example, closed-center system versus open-center system.
After installation of external valve and components, perform following
steps for setup and operation:
-
Set machine SCV, that external valve utilizes, to continuous
flow.
-
Set External SCV switch to detent.
NOTE: Status on Implement Steer Main page now reads Ok.
-
Adjust SCV Max Flow (%) for desired performance.
|
|
BA31779,00006B7-19-20131119
|
|