Task selected, recording is on, the operation mandatory details
are not defined.
|
No operation details defined. Go to GreenStar setup and enter
operation info.
|
|
Invalid prescription
|
Prescription file is invalid. -Verify rate units on prescription
are correct.
|
|
Totals: Client Undefined
|
Alarm issued stating that the user must select a Client to view
totals.
|
|
Totals: Client and Farm defined, Field undefined.
|
Alarm issued stating that the user must select a Field to view
Field, Task, or Load Totals.
|
|
Totals: CFF, Task, and Operation defined, Crop/Product Type
undefined.
|
No Alarm. Operation defaulted to ““ and Task Totals are listed.
|
|
Totals: CFF and Crop/Product Type defined, Task and/or Operation
undefined.
|
Alarm issued stating that the user must select a Task and Operation
to view Field or Load Totals.
|
|
Totals: Client, Crop and Task defined, Farm and Field undefined.
|
No Alarm. Task and Operation defaulted to ““ and Crop Totals
are listed.
|
|
Reset totals to zero
|
Are you sure you want to zero the totals listed below?
|
|
In order to record a product application, you must choose a
product type and product name on one of the ADD PRODUCT boxes. Choices
will be CHANGE, which takes the user to the product summary screen,
or REMOVE OPERATION which will flash up the "Are you sure you want
to delete this operation" message.
|
In order to record a product application, you must choose a
product type and product name on one of the Add Product boxes.
|
|
When no products are specified in an application
|
No products are specified, please select a product.
|
|
An alarm shall be issued if there is a prescription selected
in Field Doc but not selected in the planter/sprayer setup.
|
Prescription available but not selected. Go to implement setup
to select the prescription as the rate.
|
|
An alarm will be issued if Field Doc has a prescription selected,
but the planter/sprayer is outside the field boundary for the prescription.
"Default Rx Rate Used.
|
Machine outside the field boundary for the prescription. Default
Prescription rate being used.
|
|
At power-up, An alarm will be issued if a prescription is being
used and the prescription multiplier for an operation is not set to
100%.
|
Prescription Multiplier not 100%.
|
|
Implement width set to zero.
|
Implement width is set to zero. Implement width is required
to record data.
|
|
Anywhere: User selects the DOCUMENTATION button before filling
out CFFT
|
You must choose a Client, Farm, Field, Task from the Resources
button
|
|
Communication lost with a connected controller.
|
Communication lost with controller. If controller was not disconnected,
check connections and cycle power. If controller was disconnected
please review operations selected.
|
|
Field Doc didn't get some periodic messages
|
Communication lost with controller. If controller was not disconnected,
check connections and cycle power. If controller was disconnected
please review operations selected.
|
| |
Prescription available but not selected. Check setup on the
implement to ensure prescription is selected as the rate.
|
|
Air Cart Setup: Air cart is on the bus, 1st tank has been defined
with an operation, Second tank is created with the same operation
type as the first tank.
|
You are creating another seeding (application) operation. Would
you like this to be the same as the Front (Middle)(Rear) Tank seeding
(application) operation?
|
|
Air Cart Setup: User selects enter for the previous message
|
Please enter the tank ratios for each tank. (if applicable)
|
|
Air Cart Setup: User enters tank ratios that do not add to 100
|
Tank ratios must add to 100
|
|
SeedStar selects Rx but Documentation doesn't have Rx selected.
|
No prescription file for selected field. -Verify field and operation
are correct. -Verify prescription is on USB drive. -Resave prescription
to drive if necessary.
|
|
Tank Mix Screen: User attempts to add a second ingredient in
a tank mix without a carrier or base solution rate
|
You must enter a carrier and base solution rate before building
a tank mix
|
|
Incorrect model is possibly selected
|
The RS232 controller model selected is incorrect. Please verify
and reenter manufacturer and model number.
|
|
Recording is not currently allowed
|
Recording is not currently allowed. Verify settings on RS232
controller.
|
|
Alarm for manual controller when target rate changes
|
Target rate has changed. Alarm for manual controller.
|
|
Alarm when Raven is communicating everything but an actual rate
|
Raven controller not communicating actual rate. Verify Raven
controller settings and connections to the display.
|
|
Special handling will be needed for each controller to monitor
the health of the connection
|
Communication problem with controller. Check connections to
controller.
|