Trouble Code Pop-Up Boxes—Documentation Software

FAULT CONDITION FAULT DESCRIPTION

ALARM TEXT

Task selected, recording is on, the operation mandatory details are not defined.

No operation details defined. Go to GreenStar setup and enter operation info.

Invalid prescription

Prescription file is invalid. -Verify rate units on prescription are correct.

Totals: Client Undefined

Alarm issued stating that the user must select a Client to view totals.

Totals: Client and Farm defined, Field undefined.

Alarm issued stating that the user must select a Field to view Field, Task, or Load Totals.

Totals: CFF, Task, and Operation defined, Crop/Product Type undefined.

No Alarm. Operation defaulted to “­“ and Task Totals are listed.

Totals: CFF and Crop/Product Type defined, Task and/or Operation undefined.

Alarm issued stating that the user must select a Task and Operation to view Field or Load Totals.

Totals: Client, Crop and Task defined, Farm and Field undefined.

No Alarm. Task and Operation defaulted to “­“ and Crop Totals are listed.

Reset totals to zero

Are you sure you want to zero the totals listed below?

In order to record a product application, you must choose a product type and product name on one of the ADD PRODUCT boxes. Choices will be CHANGE, which takes the user to the product summary screen, or REMOVE OPERATION which will flash up the "Are you sure you want to delete this operation" message.

In order to record a product application, you must choose a product type and product name on one of the Add Product boxes.

When no products are specified in an application

No products are specified, please select a product.

An alarm shall be issued if there is a prescription selected in Field Doc but not selected in the planter/sprayer setup.

Prescription available but not selected. Go to implement setup to select the prescription as the rate.

An alarm will be issued if Field Doc has a prescription selected, but the planter/sprayer is outside the field boundary for the prescription.  "Default Rx Rate Used.

Machine outside the field boundary for the prescription.  Default Prescription rate being used.

At power-up, An alarm will be issued if a prescription is being used and the prescription multiplier for an operation is not set to 100%.

Prescription Multiplier not 100%.

Implement width set to zero.

Implement width is set to zero. Implement width is required to record data.

Anywhere: User selects the DOCUMENTATION button before filling out CFFT

You must choose a Client, Farm, Field, Task from the Resources button

Communication lost with a connected controller.

Communication lost with controller. If controller was not disconnected, check connections and cycle power. If controller was disconnected please review operations selected.

Field Doc didn't get some periodic messages

Communication lost with controller. If controller was not disconnected, check connections and cycle power. If controller was disconnected please review operations selected.

 

Prescription available but not selected. Check setup on the implement to ensure prescription is selected as the rate.

Air Cart Setup: Air cart is on the bus, 1st tank has been defined with an operation, Second tank is created with the same operation type as the first tank.

You are creating another seeding (application) operation. Would you like this to be the same as the Front (Middle)(Rear) Tank seeding (application) operation?

Air Cart Setup: User selects enter for the previous message

Please enter the tank ratios for each tank. (if applicable)

Air Cart Setup: User enters tank ratios that do not add to 100

Tank ratios must add to 100

SeedStar selects Rx but Documentation doesn't have Rx selected.

No prescription file for selected field. -Verify field and operation are correct. -Verify prescription is on USB drive. -Resave prescription to drive if necessary.

Tank Mix Screen: User attempts to add a second ingredient in a tank mix without a carrier or base solution rate

You must enter a carrier and base solution rate before building a tank mix

Incorrect model is possibly selected

The RS232 controller model selected is incorrect. Please verify and reenter manufacturer and model number.

Recording is not currently allowed

Recording is not currently allowed. Verify settings on RS232 controller.

Alarm for manual controller when target rate changes

Target rate has changed. Alarm for manual controller.

Alarm when Raven is communicating everything but an actual rate

Raven controller not communicating actual rate. Verify Raven controller settings and connections to the display.

Special handling will be needed for each controller to monitor the health of the connection

Communication problem with controller. Check connections to controller.