Fault Code Number
|
Description
|
Recommended Initial Action
|
|
GRC 158.03
|
Switched Supply Voltage High
|
Contact dealer.
|
|
GRC 158.04
|
Switched Supply Voltage Low
|
Contact dealer.
|
|
GRC 628.12
|
Control Unit Programming
|
Contact dealer.
|
|
GRC 629.12
|
Control Unit Fault
|
Contact dealer.
|
|
GRC 630.13
|
Configure System
|
See owners manual and calibrate system.
|
|
GRC 630.14
|
SeedStar Configuration Conflict
|
Verify SeedStar and GreenStar Rate Controller settings match.
|
|
GRC 639.14
|
CAN Communications Error
|
Contact dealer.
|
|
GRC 1871.02
|
No Height Switch data
|
Check settings on Implement tab.
|
|
GRC 1871.14
|
Multiple Height Switches
|
Check settings on Implement tab.
|
|
GRC 3130.17
|
Low Tank Volume
|
Check tank level shown on display. Adjust if necessary.
|
|
GRC 3132.03
|
Pressure Above Maximum Level - Sensor 1
|
Check settings on the Alarms tab. Adjust if necessary.
|
|
GRC 3132.04
|
Pressure Below Minimum Level - Sensor 1
|
Check settings on the Alarms tab. Adjust if necessary.
|
|
GRC 3133.01
|
Solution Pump Dry
|
Check actual tank level and flow meter.
|
|
GRC 3133.31
|
Solution Pump Not On
|
Check Enable Pump checkbox to turn on pump.
|
|
GRC 3509.03
|
Sensor Supply Voltage for Pressure Sensor High
|
Contact dealer.
|
|
GRC 3509.04
|
Sensor Supply Voltage for Pressure Sensor Low
|
Contact dealer.
|
|
GRC 3510.03
|
Sensor Supply Voltage for Flow Meter High
|
Contact dealer.
|
|
GRC 3510.04
|
Sensor Supply Voltage for Flow Meter Low
|
Contact dealer.
|
|
GRC 521529.03
|
Pressure Above Maximum Level - Sensor 2
|
Check settings on the Alarms tab. Adjust if necessary.
|
|
GRC 521529.04
|
Pressure Below Minimum Level - Sensor 2
|
Check settings on the Alarms tab. Adjust if necessary.
|
|
GRC 523350.30
|
Implement Height Switch Malfunction
|
Verify implement height switch is installed.
|
|
GRC 523394.00
|
Unexpected Product Flow Detected
|
Contact dealer.
|
|
GRC 523394.01
|
No Flow Detected
|
Check actual tank level and flow meter.
|
|
GRC 523394.16
|
Application Rate Above Maximum Level
|
Check settings on the Alarms tab. Adjust if necessary.
|
|
GRC 523394.18
|
Application Rate Below Minimum Level
|
Check settings on the Alarms tab. Adjust if necessary.
|
|
GRC 523823.00
|
Application Speed Exceeded
|
Operate at lower vehicle speed.
|
|
GRC 523935.06
|
Driver Over-Current
|
Contact dealer.
|
|
GRC 523966.31
|
GreenStar Rate Controller Limp Home Mode Enabled
|
Check limp home fuse in GreenStar Rate Controller harness.
|
|
GRC 524158.02
|
Planter Adapter Harness Fault
|
Contact dealer.
|