Flow Control Valves
| |
NH3
|
Liquid Fertilizer
|
Sprayers
|
|
Standard
|
X
|
X
|
X
|
|
Fast
|
X
|
X
|
X
|
|
Fast Close
|
X
|
X
|
X
|
|
PWM
|
|
X
|
X
|
|
PWM Close
|
|
X
|
X
|
-
Flow Control Valve types: Standard, Fast, Fast Close, PWM, and
PWM Close.
-
Flow Control Valves that require 12V power to open.
-
Flow Control Valves that require less than 2.5 amp of current.
Flow Control Valve Types
IMPORTANT: For PWM and PWM Close Control Valve systems, it is
recommended that an external solution pump on/off switch is wired
into the cab, if not already present, allowing the operator to shut
off the solution pump. Solution pump damage could occur if it is run
without solution in it. PWM Control Valve System: When
the master switch is shut off on a PWM Control Valve System, it will
close the section on/off valve(s) stopping product flow. The PWM Valve
will remain at its current position allowing hydraulic flow to continue
to the solution pump which will allow the solution pump to continue
running. An external solution pump on/off switch will allow the operator
to shut off the solution pump.
PWM Close Control Valve System: When the master switch is shut
off on a PWM Close Control Valve System, it will shut off the solution
pump. An external solution pump on/off switch can be more user-friendly
and familiar for a sprayer operator to shut off the solution pump
if the solution tank runs empty.
Refer to the solution pump manufacturer’s Operators Manual
for more information.
-
Standard Control Valves
Standard control valves are used in dual-valve systems and are
used in conjunction with an on/off valve. The on/off valve closes
in order to stop product flow and the standard control valve remains
in its current position. Upon the re-opening of the on/off valve,
the standard control valve should need little to no adjustment, assuming
the target flow rate has not changed dramatically.
-
Fast Close Control Valves
Fast Close control valves are used in single-valve systems.
Due to its quick response time, a fast close valve eliminates the
need for an additional on/off valve. The fast close valve serves as
the rate control valve and will also completely close when it is necessary
to stop product flow. To start product flow once again, the fast close
valve opens and quickly ramps flow back up to achieve the target application
rate.
-
Fast Control Valves
Fast control valves are used in dual-valve systems and are used
in conjunction with an on/off valve. The on/off valve closes in order
to stop product flow and the fast control valve remains in its current
position. Upon re-opening the on/off valve, the fast control valve
should need little to no adjustment, assuming the target flow rate
has not changed dramatically.
-
PWM Control Valves
PWM Control Valves are used in dual-valve systems and are used
in conjunction with an on/off valve. The on/off valve closes to stop
flow and the PWM Valve remains in its current position. Upon reopening
the on/off valve, the PWM Valve should need little to no adjustment,
assuming the target flow has not changed dramatically.
-
PWM Close Control Valves
PWM Close Control Valves are used in single-valve systems. Due
to its quick response time the PWM Close Valve eliminates the need
for an additional on/off valve. The PWM valve serves as the rate control
valve and will also completely close when it is necessary to completely
stop flow. To start product flow once again, the PWM close valve opens
and quickly ramps flow back up to achieve the target application rate.
NOTE: Fast and Fast Close or PWM and PWM Close Valves are physically
the same with the only difference being how the GreenStar Rate Controller
controls them.
Flowmeters
-
Flowmeters requiring 5V or 12V power supply.
-
Flowmeters with square wave signal type.
Flowmeter Supplemental Information
-
For a Flowmeter requiring a 5V power supply, use power provided
through the pin labeled Flowmeter #1 5vdc.
-
For a Flowmeter requiring a 12V power supply, use power provided
through the pin labeled ECU Power.
Pressure Sensors
-
Pressure sensors requiring 5V or 12V power supply
-
Pressure sensors that are voltage based with an output voltage
range of 0V to 5V
Planter Compatibility
The GreenStar Rate Controller can communicate with SeedStar
controllers to control engagement of hydraulic variable rate motors
on the following John Deere planter configurations:
-
John Deere planters with Hydraulic Variable Rate Motors will
have 2 to 4 sections available.
-
John Deere planters with Non-CAN based frame control.
The GreenStar Rate Controller can control engagement of electric
clutches or solenoids on the following ground drive configurations:
-
Planters with individual row clutches (Tru Count) will have
1 to 16 sections available.
-
Planters with Non-CAN based frame control.
-
Planters with existing ½, ⅓, or ¼ electric
disconnect clutches will have 2 to 4 sections available dependent
on the disconnect sections.
Implement Height Switch
-
An implement height switch is REQUIRED for NH3 and planter applications.
-
An implement height switch is OPTIONAL for liquid fertilizer
applications.
|
|
CZ76372,00001E9-19-20101027
|
|