Observable Symptoms

SymptomProblemSolution

Unexpected application rate.

Incorrect rate type selected (gal./min. or gal./acre).

Select correct rate type.

Product does not shut off.

Valve does not respond to commands.

Select correct valve type.

2-Wire valve selection is not available.

Dual boom is selected.

Disable dual boom.

 

More than seven sections are selected.

Assign less than eight sections.

Erratic implement section is not turning on or off.

Incorrect section valve type selected.

Select correct section valve type.

Application is erratic.

Calibration number is not set correctly.

Enter correct calibration number.

Trouble code is displayed for high pressure.

System pressure is high.

Select flow return in system setup.

Trouble code is displayed for unexpected flow.

Constant flow is disabled when using a constant flow system with boom valve closed.

Select constant flow in system setup.

Flow is not applying at desired rate.

Incorrect application rate.

Ensure 10 gal./10 L unit is used.

 

Minimum Flow rate feature causes over-application in areas where machine speed is low enough to activate Minimum Flow Rate.

Set minimum flow rate to 0 to disable feature.

 

Flow per minute is not an option.

Ensure pressure sensor is installed.

Raven calibration number of 0043 is not optimal for controller.

PWM or PWM Close control valve is not referenced in chart.

Fine-tune calibration value for optimal performance.

System detects implement is down for an extensive period of time.

Height switch is disabled.

If height switch indicator does not match machine operation, service height switch.

Unexpected chemical flow detected.

Controller attempts to close section valves, but detects flow on a sprayer or liquid fertilizer system.

Shut off solution pump.

Unable to set up minimum and maximum alarms.

Minimum and maximum alarms are disabled.

Ensure pressure sensor is installed and configured.

Unable to set values.

System not allowing changes to values or settings.

Ensure Master Switch is on.

Unexpected anhydrous ammonia flow detected.

Controller attempts to close On/Off valve, but still detects flow.

Select button to turn off control valve.

 

Controller attempts to close all valves, but still detects flow.

Follow instructions on Warning page on display.

Pressure sensors are not configured.

Pressure sensor 2 is not an option.

Ensure both sensors are configured.

Pump information drop-down does not appear.

Pump Enable checkbox is selected.

Ensure Enable Pump checkbox is not selected.

Unwanted minimum flow rate activation.

Over application in low speed areas.

Set minimum flow rate to 0 to disable function.

HC94949,0000624-19-20150107