Unexpected application rate.
Select correct rate type.
Product does not shut off.
Select correct valve type.
2-Wire valve selection is not available.
Disable dual boom.
More than seven sections are selected.
Assign less than eight sections.
Erratic implement section is not turning on or off.
Select correct section valve type.
Application is erratic.
Enter correct calibration number.
Trouble code is displayed for high pressure.
Select flow return in system setup.
Trouble code is displayed for unexpected flow.
Select constant flow in system setup.
Flow is not applying at desired rate.
Ensure 10 gal./10 L unit is used.
Minimum Flow rate feature causes over-application in areas where machine speed is low enough to activate Minimum Flow Rate.
Set minimum flow rate to 0 to disable feature.
Flow per minute is not an option.
Ensure pressure sensor is installed.
Raven calibration number of 0043 is not optimal for controller.
Fine-tune calibration value for optimal performance.
System detects implement is down for an extensive period of time.
If height switch indicator does not match machine operation, service height switch.
Unexpected chemical flow detected.
Shut off solution pump.
Unable to set up minimum and maximum alarms.
Ensure pressure sensor is installed and configured.
Unable to set values.
Ensure Master Switch is on.
Unexpected anhydrous ammonia flow detected.
Select button to turn off control valve.
Controller attempts to close all valves, but still detects flow.
Follow instructions on Warning page on display.
Pressure sensors are not configured.
Ensure both sensors are configured.
Pump information drop-down does not appear.
Ensure Enable Pump checkbox is not selected.
Unwanted minimum flow rate activation.
Set minimum flow rate to 0 to disable function.
HC94949,0000624-19-20150107