Control Valve Calibration Number Tuning

PC14715-UN-10FEB12
A - XX: Valve Speed
B - Y: Overshoot Reduction
C - Z: % Error Allowed
The control valve calibration number is set up in the following
format XXYZ.
The numbers work similar for all control valve types in spinner
and conveyor configurations.
XX adjusts how fast the valve reacts
to error between target and actual speeds. If the control is too slow,
increase this value. If the control is too fast or fluctuates constantly,
reduce this value. Input range is 1-99. Typical values are between
25-75.
Y adjusts overshoot when controlling
to a speed change. If the system overshoots the target, increase this
number. If control is slow reacting to a speed change, reduce this
number. Input range is 0-9. Typical values are between 2-4.
XX and Y can affect each other when changed. Adjusting one value may require
a change to the other. It is best to adjust the XX value first to ensure that the system is quick to react.
Then change Y value as needed.
Z adjusts control deadband. It represents
the error (% of target conveyor/spinner speed) allowed when reaching
a target speed. To make the controller more responsive to errors,
lower the value. To make the controller more accepting of errors,
increase the value. If oscillation or chasing of the target speed
occurs, increase this number. The input range is between 0-9. Typical
starting value is 3.
|
|
HC94949,0000683-19-20141205
|
|