Driver Outputs Table

Driver Number

Standard Sprayer (3-wire)

Hardi Sprayer (2-wire)

NH3 Tool

Planters

Driver 1

Section 1

Section 1 (+)

Section 1

Clutch 1

Driver 2

Section 2

Section 1 (-)

Section 2

Clutch 2

Driver 3

Section 3

Section 2 (+)

Section 3

Clutch 3

Driver 4

Section 4

Section 2 (-)

Section 4

Clutch 4

Driver 5

Section 5

Section 3 (+)

Section 5

Clutch 5

Driver 6

Section 6

Section 3 (-)

Section 6

Clutch 6

Driver 7

Section 7

Section 4 (+)

Section 7

Clutch 7

Driver 8

Section 8

Section 4 (-)

Section 8

Clutch 8

Driver 9

Section 9 or Left Fence Row

Section 5 (+) or Agitator (+)

Section 9

Clutch 9

Driver 10

Section 10 or Right Fence Row

Section 5 (-) or Agitator (-)

Section 10

Clutch 10

Driver 11

Agitator Valve

Section 6 (+) or Left Fence Row

 

Clutch 11

Driver 12

Return Valve

Section 6 (-) or Right Fence Row

 

Clutch 12

Driver 13

 

Section 7 (+) or Return (-)

Master On/Off Valve

Clutch 13

Driver 14

 

Section 7 (-) or Return (+)

 

Clutch 14

Driver 15

Control (+)

Control (+)

Control (+)

Clutch 15

Driver 16

Control (-)

Control (-)

Control (-)

Clutch 16

NOTE: Enabling optional features such as fence rows nozzles and agitators will reduce the number of section controls. For example, configuring a Hardi sprayer to use an agitator valve will limit the number of boom section controls to four. Refer to table in the GreenStar Rate Controller Overview section.

JS56696,0000755-19-20100517