Fault Code Number
|
Description
|
Recommended Initial Action
|
|
SBC 000168.03
|
Switched Supply Voltage High
|
System voltage is above 15.5 V. for 5 seconds.
|
|
SBC 000168.04
|
Switched Supply Voltage Low
|
System voltage is below 10.0 V. for 5 seconds.
|
|
SBC 000628.02
|
Controller Memory Corrupted
|
Contact dealer.
|
|
SBC 000628.12
|
Controller Unit Programming
|
Wait until GreenStar Rate Control Switch Box has finished programming.
If programming is hung up, contact dealer
|
|
SBC 000629.12
|
Controller Unit Fault
|
Contract dealer.
|
|
SBC 000639.14
|
CAN Communication Error
|
CAN Bus problem or GreenStar Rate Controller Switch Box has
a CAN Bus error. Contract dealer.
|
|
SBC 523910.02
|
Controller Memory Corrupted
|
Contract dealer.
|
|
SBC 524058.02
|
Master Switch Conflict
|
Master switch digital inputs are not in a valid state. Contract
dealer.
|