Adjust Control Valve

PC22365-UN-31MAR16

PC22366-UN-31MAR16
PWM Setup Button
Valve type selected in the setup wizard may need adjustment
for specific applications.
Select Control Valve Setup button to adjust control valve.
Default Valve Values
| |
Standard
|
Fast Close
|
Fast
|
PWM
|
PWM Close
|
|
Valve Response Rate (1—100)
|
50
|
50
|
50
|
50
|
50
|
|
Control Deadband (%)
|
2
|
2
|
2
|
2
|
2
|
|
Valve Delay (sec)
|
0.0
|
|
0.0
|
0.0
|
|
|
Valve Advance (sec)
|
0.0
|
|
0.0
|
|
|
|
Control Effort (%)
|
35
|
3
|
3
|
|
|
Valve Response Rate — Enter value for aggressiveness of
rate controller as it approaches target rate. A value that is too
high may lead to oscillation. While a value too low may take a long
time to reach target rate.
Control Deadband — Enter percent of rate tolerance for
control valve. For example, if 2% is entered, rate controller attempts
to adjust flow rate until actual rate is within 2% of target rate.
Valve Delay — Enter amount of time in seconds between
when first section is turned on and rate controller begins to control
flow rate. This is useful when starting product application at lower
speeds, such as coming out of headland areas.
Valve Advance — Enter amount of time in seconds rate controller
commands control valve to open after all sections are turned off.
This may be used in conjunction with valve delay for low rate applications
to build up pressure when master switch is turned on.
Control Effort — Enter minimum percentage power needed
for control valve to change position.
PWM (Pulse Width Modulation) Setup Button
If a PWM valve was selected, select PWM Setup button for additional
options.
Coil Frequency — Frequency of pulses sent to PWM valve.
(Reference valve manufacturer Operator’s Manual for the
recommended settings.)
High Limit — Maximum PWM percent rate controller allows
system to reach when product is applying.
Low Limit — Minimum PWM percent rate controller allows
system to reach when product is applying.
PWM Standby (PWM valve) — Duty cycle rate controller maintains
when all sections are closed.
PWM Startup (PWM close valve) — Duty cycle rate controller
commands to when valve is opened.
|
|
RW00482,0000649-19-20160411
|
|