DTC
|
Description
|
Solution
|
|
158.03
|
Switched Supply Voltage High
|
Contact your John Deere dealer or qualified service provider.
|
|
158.04
|
Switched Supply Voltage Low
|
Contact your John Deere dealer or qualified service provider.
|
|
630.13
|
System configuration or calibration required
|
(Reference Operator’s Manual and calibrate system.)
|
|
3132.04
|
Pressure 1 — Sensor not detected
|
Verify pressure sensor installation.
|
|
3132.13
|
Pressure 1 — Sensor not calibrated
|
(Reference Operator’s Manual and calibrate system.)
|
|
3132.16
|
Pressure 1 — Pressure above maximum set point
|
Check settings within Alarms tab and adjust as needed.
Menu button > John Deere Rate Controller 2000 button > Setup
softkey > Alarms tab.
|
|
3132.18
|
Pressure 1 — Pressure below minimum set point
|
Check settings within Alarms tab and adjust as needed.
Menu button > John Deere Rate Controller 2000 button > Setup
softkey > Alarms tab.
|
|
4305.00
|
Application speed exceeded
|
Operate at lower application speeds.
|
|
4305.02
|
Speed is below operational speed
|
Operate at higher application speeds.
|
|
517002.04
|
Pressure 2 — Sensor not detected
|
Verify pressure sensor installation.
|
|
517002.13
|
Pressure 2 — Sensor not calibrated
|
(Reference Operator’s Manual and calibrate system.)
|
|
517002.16
|
Pressure 2 — Pressure above maximum set point
|
Check settings within Alarms tab and adjust as needed.
Menu button > John Deere Rate Controller 2000 button > Setup
softkey > Alarms tab.
|
|
517002.18
|
Pressure 2 — Pressure below minimum set point
|
Check settings within Alarms tab and adjust as needed.
Menu button > John Deere Rate Controller 2000 button > Setup
softkey > Alarms tab.
|
|
517100.00
|
Product 1 Rate — No rate expected
|
Contact your John Deere Dealer or qualified service provider.
|
|
517100.01
|
Product 1 Rate — No rate detected
|
Contact your John Deere Dealer or qualified service provider.
|
|
517100.15
|
Product 1 Rate — Rate above target
|
Check settings within Alarms tab and adjust as needed.
Menu button > John Deere Rate Controller 2000 button > Setup
softkey > Alarms tab.
|
|
517100.17
|
Product 1 Rate — Rate below target
|
Check settings within Alarms tab and adjust as needed.
Menu button > John Deere Rate Controller 2000 button > Setup
softkey > Alarms tab.
|
|
517100.18
|
Product 1 Rate — Volume per minute below minimum
|
Check settings within Alarms tab and adjust as needed.
Menu button > John Deere Rate Controller 2000 button > Setup
softkey > Alarms tab.
|
|
517199.15
|
New direct injection pump detected
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517210.16
|
Product 2 Injection — High inlet vacuum pressure
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517211.18
|
Product 2 Injection — Low pump efficiency
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517212.07
|
Product 2 Injection — Motor/encoder calibration error
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517213.17
|
Product 2 Injection — Pump lost communication
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517214.01
|
Product 2 Injection — Tank empty
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517215.15
|
Product 2 Injection — Rate above target
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517215.17
|
Product 2 Injection — Rate below target
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517216.01
|
Product 2 Injection — Injection pressure below carrier
pressure
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517216.02
|
Product 2 Injection — Pressure sensor not detected
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517216.16
|
Product 2 Injection — Pressure above maximum set point
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517217.16
|
Product 2 Injection — Target rate above pump maximum
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517217.18
|
Product 2 Injection — Target rate below pump minimum
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517218.04
|
Product 2 Injection — Motor voltage low
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517219.07
|
Product 2 Injection — Pump fault detected
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517220.16
|
Product 3 Injection — High inlet vacuum pressure
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517221.18
|
Product 3 Injection — Low pump efficiency
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517222.07
|
Product 3 Injection — Motor/encoder calibration error
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517223.17
|
Product 3 Injection — Pump lost communication
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517224.01
|
Product 3 Injection — Tank empty
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517225.15
|
Product 3 Injection — Rate above target
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517225.17
|
Product 3 Injection — Rate below target
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517226.01
|
Product 3 Injection — Injection pressure below carrier
pressure
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517226.02
|
Product 3 Injection — Pressure sensor not detected
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517226.16
|
Product 3 Injection — Pressure above maximum set point
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517227.16
|
Product 3 Injection — Target rate above pump maximum
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517227.18
|
Product 3 Injection — Target rate below pump minimum
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517228.04
|
Product 3 Injection — Motor voltage low
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517229.07
|
Product 3 Injection — Pump fault detected
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517230.16
|
Product 4 Injection — High inlet vacuum pressure
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517231.18
|
Product 4 Injection — Low pump efficiency
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517232.07
|
Product 4 Injection — Motor/encoder calibration error
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517233.17
|
Product 4 Injection — Pump lost communication
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517234.01
|
Product 4 Injection — Tank empty
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517235.15
|
Product 4 Injection — Rate above target
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517235.17
|
Product 4 Injection — Rate below target
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517236.01
|
Product 4 Injection — Injection pressure below carrier
pressure
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517236.02
|
Product 4 Injection — Pressure sensor not detected
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517236.16
|
Product 4 Injection — Pressure above maximum set point
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517237.16
|
Product 4 Injection — Target rate above pump maximum
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517237.18
|
Product 4 Injection — Target rate below pump minimum
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517238.04
|
Product 4 Injection — Motor voltage low
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517239.07
|
Product 4 Injection — Pump fault detected
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517240.16
|
Product 5 Injection — High inlet vacuum pressure
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517241.18
|
Product 5 Injection — Low pump efficiency
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517242.07
|
Product 5 Injection — Motor/encoder calibration error
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517243.17
|
Product 5 Injection — Pump lost communication
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517244.01
|
Product 5 Injection — Tank empty
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517245.15
|
Product 5 Injection — Rate above target
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517245.17
|
Product 5 Injection — Rate below target
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517246.01
|
Product 5 Injection — Injection pressure below carrier
pressure
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517246.02
|
Product 5 Injection — Pressure sensor not detected
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517246.16
|
Product 5 Injection — Pressure above maximum set point
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517247.16
|
Product 5 Injection — Target rate above pump maximum
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517247.18
|
Product 5 Injection — Target rate below pump minimum
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517248.04
|
Product 5 Injection — Motor voltage low
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517249.07
|
Product 5 Injection — Pump fault detected
|
(Reference ravenhelp.com for more information on Raven
Direct Injection systems.)
|
|
517520.00
|
Section valve master open when it should be closed
|
Contact your John Deere dealer or qualified service provider.
|
|
517520.01
|
Section valve master closed when it should be open
|
Contact your John Deere dealer or qualified service provider.
|
|
517521.00
|
Section valve 1 open when it should be closed
|
Contact your John Deere dealer or qualified service provider.
|
|
517521.01
|
Section valve 1 closed when it should be open
|
Contact your John Deere dealer or qualified service provider.
|
|
517522.00
|
Section valve 2 open when it should be closed
|
Contact your John Deere dealer or qualified service provider.
|
|
517522.01
|
Section valve 2 closed when it should be open
|
Contact your John Deere dealer or qualified service provider.
|
|
517523.00
|
Section valve 3 open when it should be closed
|
Contact your John Deere dealer or qualified service provider.
|
|
517523.01
|
Section valve 3 closed when it should be open
|
Contact your John Deere dealer or qualified service provider.
|
|
517524.00
|
Section valve 4 open when it should be closed
|
Contact your John Deere dealer or qualified service provider.
|
|
517524.01
|
Section valve 4 closed when it should be open
|
Contact your John Deere dealer or qualified service provider.
|
|
517525.00
|
Section valve 5 open when it should be closed
|
Contact your John Deere dealer or qualified service provider.
|
|
517525.01
|
Section valve 5 closed when it should be open
|
Contact your John Deere dealer or qualified service provider.
|
|
517526.00
|
Section valve 6 open when it should be closed
|
Contact your John Deere dealer or qualified service provider.
|
|
517526.01
|
Section valve 6 closed when it should be open
|
Contact your John Deere dealer or qualified service provider.
|
|
517527.00
|
Section valve 7 open when it should be closed
|
Contact your John Deere dealer or qualified service provider.
|
|
517527.01
|
Section valve 7 closed when it should be open
|
Contact your John Deere dealer or qualified service provider.
|
|
517528.00
|
Section valve 8 open when it should be closed
|
Contact your John Deere dealer or qualified service provider.
|
|
517528.01
|
Section valve 8 closed when it should be open
|
Contact your John Deere dealer or qualified service provider.
|
|
517529.00
|
Section valve 9 open when it should be closed
|
Contact your John Deere dealer or qualified service provider.
|
|
517529.01
|
Section valve 9 closed when it should be open
|
Contact your John Deere dealer or qualified service provider.
|
|
517530.00
|
Section valve 10 open when it should be closed
|
Contact your John Deere dealer or qualified service provider.
|
|
517530.01
|
Section valve 10 closed when it should be open
|
Contact your John Deere dealer or qualified service provider.
|
|
517540.01
|
Valve power sense circuit 1 error
|
Contact your John Deere dealer or qualified service provider.
|
|
517541.01
|
Valve power sense circuit 2 error
|
Contact your John Deere dealer or qualified service provider.
|
|
517542.01
|
Valve power harness error
|
Contact your John Deere dealer or qualified service provider.
|
|
517550.01
|
Low current power loss
|
Contact your John Deere dealer or qualified service provider.
|
|
517560.01
|
Product Pump 1 — Pump dry
|
Turn off master foot switch and verify there is product within
the tank.
|
|
517560.07
|
Product Pump 1 — Raven AccuFlow HP Plus boost pump
fault
|
Contact your John Deere dealer or qualified service provider.
|
|
517900.01
|
Test canceled
|
No checks needed.
|
|
523160.17
|
Product bin/tank 1 volume has fallen below the operator designated
minimum level
|
Check settings within Alarms tab and adjust as needed.
Menu button > John Deere Rate Controller 2000 button > Setup
softkey > Alarms tab.
|
|
523350.30
|
Implement height switch malfunction
|
Verify that implement is functioning properly.
|