Control Valves and Sensors
IMPORTANT: For pulse width modulation (PWM) and PWM close control
valve systems, it is recommended that an external solution pump on-off
switch is wired into the cab. This allows the operator to shut off
the solution pump. Solution pump damage could occur if it is run without
solution in it. When the master switch is shut off on
a PWM control valve system, it closes the section on-off valve(s)
and stops product flow. The PWM valve remains at its current position,
which allows hydraulic flow to continue to the solution pump and allows
the solution pump to continue running. An external solution pump on-off
switch allows the operator to shut off the solution pump.
When the master switch is shut off on a PWM close control valve
system, it will shut off the solution pump. An external solution pump
on-off switch can be more user-friendly and familiar for a sprayer
operator to shut off the solution pump if the solution tank runs empty.
(Reference solution pump manufacturer Operator’s Manual
for more information.)
| |
NH3
|
Liquid Fertilizer
|
Sprayers
|
Spreaders
|
Air Carts and Generic
|
|
Standard
|
X
|
X
|
X
|
|
|
|
Fast
|
X
|
X
|
X
|
|
|
|
Fast Close
|
X
|
X
|
X
|
|
X
|
|
PWM
|
|
X
|
X
|
X
|
|
|
PWM Close
|
|
X
|
X
|
X
|
X
|
|
Raven AccuFlow HP Plus
|
X
|
|
|
|
|
John Deere Rate Controller 2000 is compatible with:
-
Standard, fast, fast close, PWM, and PWM close type valves.
-
Valves that require 12 V to open.
-
Valves that require less than 2.5 A.
Flow Control Valve Types
-
Standard control valves are used in
dual-valve systems in conjunction with an on-off valve. The on-off
valve closes in order to stop product flow and the standard control
valve remains in its current position. Once on-off valve is reopened,
the standard control valve should need little to no adjustment, assuming
the target flow rate has not changed dramatically.
-
Fast close control valves are used
in single-valve systems. Due to its quick response time, the fast
close valve eliminates the need for an additional on-off valve. The
fast close valve serves as the rate control valve and also completely
closes when it is necessary to stop product flow. To start product
flow once again, the fast close valve opens and quickly ramps flow
back up to achieve the target application rate.
-
Fast control valves are used in dual-valve
systems in conjunction with an on-off valve. The on-off valve closes
in order to stop product flow and the fast control valve remains in
its current position. Once on-off valve is reopened, the fast control
valve should need little to no adjustment, assuming the target flow
rate has not changed dramatically.
-
PWM control valves are used in dual-valve
systems in conjunction with an on-off valve. The on-off valve closes
to stop flow and the PWM valve remains in its current position. Once
on-off valve is reopened, the PWM valve should need little to no adjustment,
assuming the target flow has not changed dramatically.
-
PWM close control valves are used
in single-valve systems. Due to its quick response time, the PWM close
valve eliminates the need for an additional on-off valve. The PWM
close valve serves as the rate control valve and also completely closes
when it is necessary to stop product flow. To start product flow once
again, the PWM close valve opens and quickly ramps flow back up to
achieve the target application rate.
NOTE: Fast and fast close or PWM and PWM close valves are physically
the same. The only difference is how the John Deere Rate Controller
2000 controls them.
Rate Sensors (Flowmeters and RPM Sensors)
-
Rate Sensors with square wave signal type.
-
Rate Sensors that require 5 V or 12 V power supply.
Pressure Sensors
NOTE: Select custom sensor if pressure sensor has 0 V output
when no pressure is present. Otherwise, No Sensor Detected warning
is displayed when pressure reading is zero.
-
Pressure sensors that are voltage-based with an output voltage
range of 0.5 V to 5 V.
-
Pressure sensors that require 5 V or 12 V power supply.
Bin Level Sensors (required for bin chaining)
A bin level switch alerts operator when the bin is low. The
optical switch senses the presence or absence of product in the bin.
When the bin level switch output voltage is low, product is absent
and the bin is nearly empty.
NH3 Boost Pump Compatibility
John Deere Rate Controller 2000 can control an anhydrous boost
pump that is included with a Raven AccuFlow HP™ Plus cooler.
(Reference Specifications section for wiring and pin out information.)
|
AccuFlow HP is a trademark of Raven Industries Inc.
|
RW00482,00006A1-19-20160616
|
|