Input/Output (I/O) Voltages

  1. PC8663
    PC8663-UN-29APR15

    Menu Button

    Select the Menu button.



  2. PC14926
    PC14926-UN-27APR12

    Application Controller 1100 Button

    Select the Application Controller 1100 button.



  3. PC12961
    PC12961-UN-13APR15

    Setup Softkey

    Select the Application Controller Setup softkey.



  4. PC21345
    PC21345-UN-09JUL15

    I/O Voltages Button

    Select the I/O Voltages button.



  5. PC19689
    PC19689-UN-12JUN14

    I/O Voltages

    Verify I/O Voltages.



I/O Voltages Page

System Definitions

Description

Reading

Integrated

External Valve

Analog In Pin 1 (Pin G2)

Wheel angle sensor voltage reading SCV 1 = 0—5 V, 2.5 V = neutral

Current voltage reading of the wheel angle sensor when plugged into the selective control valve (SCV) 1 on implement feedback harness.

Analog In Pin 2 (Pin K2)

Wheel angle sensor voltage reading SCV 3 = 0—5 V, 2.5 V = neutral

Current voltage reading of the wheel angle sensor when plugged into SCV 3 on implement feedback harness.

Analog Out Pin 1 (Pin H1)

Command SCV 1 voltage value 0—5 V, 2.5 V = neutral

When set up for SCV 1, this is the voltage commanded to the hydraulics control unit, or current command voltage of respective SCV if not in Auto mode.

When set up for SCV 1, this is the voltage reading of external SCV lever. Approximately 2.8 V is neutral. If the voltage is close to 0 V and (or) not changing with movement of the remote mount electronic SCV control lever, ensure that external valve is connected and the light is on.

Analog Out Pin 2 (Pin J1)

Command SCV 3 voltage value 0—5 V, 2.5 V = neutral

When set up for SCV 3, this is the voltage commanded to the hydraulics control unit, or current command voltage of respective SCV if not in Auto mode.

Not available with the external valve.

5 Volt Out

Supplied voltage 0—5 V for system

Voltage supplied to system should read close to 5 V.

Sensor Volt

Sensor voltage 0—5 V, with implement feedback harness plugged in, it is 5 V, with tractor SCV, it is 0 V and changes with command

Voltage coming from the hydraulics control unit system should read 5 V.

At rest and in detent, voltage is close to 0 V. While manually commanding, value changes with lever movement.

Digital In 1 (Pin G1)

External valve remote mount electronic SCV control lever, 0 = no command, 1 = command

Not available.

Value is used for the external valve SCV 1 and reads 0 at rest and changes to a 1 when moved.

Digital In 2 (Pin K1)

Value displays 1

Not available with the external valve.

Line Count

Not available for Active Implement Guidance.

AL70325,0000384-19-20180322