Not Activated
|
Desired application has not been activated on the control unit.
|
Obtain an activation code for application.
|
|
No GPS
|
No global position system (GPS) correction available.
|
Ensure that StarFire Receivers on implement and machine are connected and functioning
properly.
|
|
Cycle Power
|
Controller must be restarted to communicate with new function.
|
Shut OFF machine, wait for display to power down, then restart
machine.
|
|
No RTK
|
No real time kinematic (RTK) correction seen on selected receiver,
or RTK not currently available.
|
Activate RTK on the implement receiver and (or) machine receiver.
|
|
Update GPS SW
|
Incompatible software loaded.
|
Update software on StarFire™ Receivers to newest version.
|
|
Machine SCV is Not in Auto
|
Selective control valve (SCV) control not detented to engage
Active Implement Guidance.
|
Detent SCV to engage Active Implement Guidance. For an external
valve, detent added SCV lever.
|
|
OK
|
Active Implement Guidance is ready to operate, or is operating
without errors. Any faults are likely to be independent of the Active
Implement Guidance control system.
|
System working properly.
|
|
Implement Up
|
Implement is raised or has faulty implement height switch.
|
Ensure requirement to engage is correct.
|