System Status

  1. PC8663
    PC8663-UN-29APR15

    Menu Button

    Select the Menu button.



  2. PC14926
    PC14926-UN-27APR12

    Application Controller 1100 Button

    Select the Application Controller 1100 button.



  3. PC13072
    PC13072-UN-16NOV10

    Application Controller Main Softkey

    Select the Application Controller Main softkey.



  4. PC18007
    PC18007-UN-07NOV13

    Implement Steer Main Button

    Select the Implement Steer Main button.



  5. PC13527
    PC13527-UN-03MAY11

    Status Code Location

    A - Status Code

    Verify Status Code (A).



Status Code

Description

Solution

Not Activated

Desired application has not been activated on the control unit.

Obtain an activation code for application.

No GPS

No global position system (GPS) correction available.

Ensure that StarFire™ Receivers on implement and machine are connected and functioning properly.

Cycle Power

Controller must be restarted to communicate with new function.

Shut OFF machine, wait for display to power down, then restart machine.

No RTK

No real time kinematic (RTK) correction seen on selected receiver, or RTK not currently available.

Activate RTK on the implement receiver and (or) machine receiver.

Update GPS SW

Incompatible software loaded.

Update software on StarFire™ Receivers to newest version.

Machine SCV is Not in Auto

Selective control valve (SCV) control not detented to engage Active Implement Guidance.

Detent SCV to engage Active Implement Guidance. For an external valve, detent added SCV lever.

OK

Active Implement Guidance is ready to operate, or is operating without errors. Any faults are likely to be independent of the Active Implement Guidance control system.

System working properly.

Implement Up

Implement is raised or has faulty implement height switch.

Ensure requirement to engage is correct.

Display not readable when connected to machine.

There is no communication with the implement control unit.

Shut OFF power, check connections, and power up to reboot system.

Clean and reconnect the 4-pin DEUTSCH® connector at back of the ISO implement connector on machine.

Verify connection at the front of the implement.


StarFire is a trademark of Deere & Company

DEUTSCH is a trademark of Deutsch Co.

RW00482,0000689-19-20180313