Inputs Table—Multiple Products

Enabling optional features, such as fence-row nozzles and agitators, reduces number of section controls.

A three product implement, where the first two products are dry and the third is a liquid, uses the Generic column for the dry and liquid inputs.

(Refer to Sections in System Overview section.)

If the John Deere Rate Controller 2000 is configured for more than two products or 16 total sections, the pressure signals are transferred from the primary to the secondary pressure sensor inputs.

Input Number

NH3 Tool

Spreader

Air Cart and Generic (Multi-Product Liquid and Dry)

1

Flow meter signal

Product 1 rate sensor signal

Product 1 shaft sensor signal

2

Master valve status

Product 1 rate sensor signal (right-hand dual encoder)

Product 1 shaft sensor signal or fill flow meter signal

3

 

Product 2 rate sensor signal

Product 2 rate sensor signal

4

 

Product 2 rate sensor signal (right-hand dual encoder)

Product 2 shaft sensor signal or fill flow meter signal

5

Product 2 rate sensor signal

Product 3 rate sensor signal

Product 3 rate sensor signal

6

Valve status 4

Product 3 rate sensor signal (right-hand dual encoder)

Product 3 shaft sensor signal or fill flow meter signal

7

Valve status 5

Product 4 rate sensor signal

Product 4 rate sensor signal

8

Valve status 3

Product 4 rate sensor signal (right-hand dual encoder)

Product 4 shaft sensor signal or fill flow meter signal

9

Valve power 1 sense

Product 5 rate sensor signal

Product 5 rate sensor signal

10

 

Product 5 rate sensor signal (right-hand dual encoder) or pressure signal 5

Product 5 shaft sensor signal or pressure signal 5

11

Valve power 2 sense

   

12

Pressure signal 6

Pressure signal 6

Pressure signal 6

13

Valve status 1

Product 1 bin level signal

Product 1 bin level signal

14

Pressure signal 1 (NH3 outlet)

Pressure signal 1 (primary)

Pressure signal 1 (primary)

15

Valve status 2

Product 2 bin level signal

Product 2 bin level signal

16

Pressure signal 2 (NH3 inlet)

Pressure signal 2 (primary)

Pressure signal 2 (primary)

17

Product 2 bin level signal

Product 3 bin level signal

Product 3 bin level signal

18

Pressure signal 3

Pressure signal 3 (primary)

Pressure signal 3 (primary)

19

Valve status 7

Product 4 bin level signal

Product 4 bin level signal

20

Valve status 8

Pressure signal 4 (primary)

Pressure signal 4 (primary)

21

 

Product 5 bin level signal

Product 5 bin level signal

22

     

23

Valve status 6

 

Fan 2 RPM signal

24

Pump, fan, or spinner RPM signal

Fan or spinner RPM signal

Fan 1 RPM signal

25

Master switch

Master switch

Master switch

26

Implement height switch

Implement height switch

Implement height switch

27

Product 3 rate sensor signal

Pressure signal 4 (secondary)

Pressure signal 4 (secondary)

28

Valve status 9

Pressure signal 3 (secondary)

Pressure signal 3 (secondary)

29

Product 3 bin level signal or valve status 10

Pressure signal 2 (secondary)

Pressure signal 2 (secondary)

30

Pressure signal 4

Pressure signal 1 (secondary)

Pressure signal 1 (secondary)

AE77568,0000468-19-20181009