Diagnostic Trouble Codes (DTCs) — John Deere Rate Controller 2000

DTC

Description

Solution

10.13

Display Not Detected

Verify that display is connected and reboot system.

158.03

Switched Supply Voltage High

Check connections and diagnostic LEDs on John Deere Rate Controller 2000 and reference the Operator’s Manual.

158.04

Switched Supply Voltage Low

Check connections and diagnostic LEDs on John Deere Rate Controller 2000 and reference the Operator’s Manual.

628.12

Bad Intelligent Device or Component

Check connections and diagnostic LEDs on John Deere Rate Controller 2000 and reference the Operator’s Manual.

Reboot system if the problem persists.

630.13

System Configuration or Calibration Required

Reference Operator’s Manual and calibrate system.

3132.04

Pressure 1—Sensor Not Detected

Verify pressure sensor installation.

3132.13

Pressure 1—Sensor Not Calibrated

Reference Operator’s Manual and calibrate system.

3132.16

Pressure 1—Pressure Above Maximum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

3132.18

Pressure 1—Pressure Below Minimum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

4305.00

Application Speed Exceeded

Operate at lower application speeds.

4305.02

Speed Is Below Operational Speed

Operate at higher application speeds.

517247.04

Pressure 2—Sensor Not Detected

Verify pressure sensor installation.

517247.13

Pressure 2—Sensor Not Calibrated

Reference Operator’s Manual and calibrate system.

517247.16

Pressure 2—Pressure Above Maximum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517247.18

Pressure 2—Pressure Below Minimum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517248.00

Product 1 Rate—No Rate Expected

Verify that hydraulic system is turned off. Verify that master switch is off.

517248.01

Product 1 Rate—No Rate Detected

Verify that hydraulic system is functioning. Adjust control valve settings as needed.

517248.13

Product 1 Rate—Calibration Required

Reference Operator’s Manual and calibrate system.

517248.15

Product 1 Rate—Rate Above Target

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517248.17

Product 1 Rate—Rate Below Target

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517248.18

Product 1 Rate—Volume Per Minute Below Minimum

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517248.31

Product 1 Rate—No RPM speed

Verify that hydraulic system is functioning. Adjust control valve settings as needed.

517249.17

Product 2 Injection—Pump Lost Communication

Check injection pump connections.

517250.01

Product 2 Injection—Injection Pressure Below Carrier Pressure

Reference Raven Industries for more information on Raven Direct Injection systems.

517251.17

Product 3 Injection—Pump Lost Communication

Check injection pump connections.

517252.01

Product 3 Injection—Injection Pressure Below Carrier Pressure

Reference Raven Industries for more information on Raven Direct Injection systems.

517253.17

Product 4 Injection—Pump Lost Communication

Check injection pump connections.

517254.01

Product 4 Injection—Injection Pressure Below Carrier Pressure

Reference Raven Industries for more information on Raven Direct Injection systems.

517255.17

Product 5 Injection—Pump Lost Communication

Check injection pump connections.

517256.01

Product 5 Injection—Injection Pressure Below Carrier Pressure

Reference Raven Industries for more information on Raven Direct Injection systems.

517257.15

RPM 1—Above Maximum Threshold

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517257.17

RPM 1—Below Minimum Threshold

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517258.00

Section Valve Master Open When It Should Be Closed

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517258.01

Section Valve Master Closed When It Should Be Open

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517259.00

Section Valve 1 Open When It Should Be Closed

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517259.01

Section Valve 1 Closed When It Should Be Open

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517260.00

Section Valve 2 Open When It Should Be Closed

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517260.01

Section Valve 2 Closed When It Should Be Open

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517261.00

Section Valve 3 Open When It Should Be Closed

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517261.01

Section Valve 3 Closed When It Should Be Open

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517262.00

Section Valve 4 Open When It Should Be Closed

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517262.01

Section Valve 4 Closed When It Should Be Open

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517263.00

Section Valve 5 Open When It Should Be Closed

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517263.01

Section Valve 5 Closed When It Should Be Open

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517264.00

Section Valve 6 Open When It Should Be Closed

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517264.01

Section Valve 6 Closed When It Should Be Open

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517265.00

Section Valve 7 Open When It Should Be Closed

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517265.01

Section Valve 7 Closed When It Should Be Open

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517266.00

Section Valve 8 Open When It Should Be Closed

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517266.01

Section Valve 8 Closed When It Should Be Open

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517267.00

Section Valve 9 Open When It Should Be Closed

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517267.01

Section Valve 9 Closed When It Should Be Open

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517268.00

Section Valve 10 Open When It Should Be Closed

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517268.01

Section Valve 10 Closed When It Should Be Open

Check valve functionality.

Select Menu button > John Deere Rate Controller 2000 button > Diagnostics softkey > Test tab.

517269.01

Valve Power Sense Circuit 1 Error

Check connections and diagnostic LEDs on John Deere Rate Controller 2000 and reference the Operator’s Manual.

517270.01

Valve Power Sense Circuit 2 Error

Check connections and diagnostic LEDs on John Deere Rate Controller 2000 and reference the Operator’s Manual.

517271.01

Valve Power Harness Error

Check connections and diagnostic LEDs on John Deere Rate Controller 2000 and reference the Operator’s Manual.

517272.01

Low Current Power Loss

Check connections and diagnostic LEDs on John Deere Rate Controller 2000 and reference the Operator’s Manual.

517273.01

Product Pump 1—Pump Dry (PWM control valve)

Turn off master switch and verify that there is product within the tank.

517273.07

Product Pump 1—Raven AccuFlow HP™ Plus Boost Pump Fault

Reference Raven Industries for more information on Raven Direct Injection systems.

517273.18

Pump 1—Pump Dry (servo control valve)

Turn off master switch and verify that there is product within the tank.

517274.01

Test Canceled

No checks needed.

517296.04

Pressure 3—Sensor Not Detected

Verify pressure sensor installation.

517296.13

Pressure 3—Sensor Not Calibrated

Reference Operator’s Manual and calibrate system.

517296.16

Pressure 3—Pressure Above Maximum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517296.18

Pressure 3—Pressure Below Minimum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517297.04

Pressure 4—Sensor Not Detected

Verify pressure sensor installation.

517297.13

Pressure 4—Sensor Not Calibrated

Reference Operator’s Manual and calibrate system.

517297.16

Pressure 4—Pressure Above Maximum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517297.18

Pressure 4—Pressure Below Minimum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517298.04

Pressure 5—Sensor Not Detected

Verify pressure sensor installation.

517298.13

Pressure 5—Sensor Not Calibrated

Reference Operator’s Manual and calibrate system.

517298.16

Pressure 5—Pressure Above Maximum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517298.18

Pressure 5—Pressure Below Minimum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517299.04

Pressure 6—Sensor Not Detected

Verify pressure sensor installation.

517299.13

Pressure 6—Sensor Not Calibrated

Reference Operator’s Manual and calibrate system.

517299.16

Pressure 6—Pressure Above Maximum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517299.18

Pressure 6—Pressure Below Minimum Set Point

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517300.00

Product 2 Rate—No Rate Expected

Verify that hydraulic system is turned off. Verify master switch is off.

517300.01

Product 2 Rate—No Rate Detected

Verify that hydraulic system is functioning. Adjust control valve settings as needed.

517300.13

Product 2 Rate—Calibration Required

Reference Operator’s Manual and calibrate system.

517300.15

Product 2 Rate—Rate Above Target

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517300.17

Product 2 Rate—Rate Below Target

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517300.18

Product 2 Rate—Volume Per Minute Below Minimum

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517300.31

Product 2 Rate—No RPM speed

Verify that hydraulic system is functioning. Adjust control valve settings as needed.

517301.00

Product 3 Rate—No Rate Expected

Verify that hydraulic system is turned off. Verify master switch is off.

517301.01

Product 3 Rate—No Rate Detected

Verify that hydraulic system is functioning. Adjust control valve settings as needed.

517301.13

Product 3 Rate—Calibration Required

Reference Operator’s Manual and calibrate system.

517301.15

Product 3 Rate—Rate Above Target

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517301.17

Product 3 Rate—Rate Below Target

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517301.18

Product 3 Rate—Volume Per Minute Below Minimum

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517301.31

Product 3 Rate—No RPM Speed

Verify that hydraulic system is functioning. Adjust control valve settings as needed.

517302.00

Product 4 Rate—No Rate Expected

Verify that hydraulic system is turned off. Verify master switch is off.

517302.01

Product 4 Rate—No Rate Detected

Verify that hydraulic system is functioning. Adjust control valve settings as needed.

517302.13

Product 4 Rate—Calibration Required

Reference Operator’s Manual and calibrate system.

517302.15

Product 4 Rate—Rate Above Target

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517302.17

Product 4 Rate—Rate Below Target

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517302.18

Product 4 Rate—Volume Per Minute Below Minimum

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517302.31

Product 4 Rate—No RPM Speed

Verify that hydraulic system is functioning. Adjust control valve settings as needed.

517303.00

Product 5 Rate—No Rate Expected

Verify that hydraulic system is turned off. Verify master switch is off.

517303.01

Product 5 Rate—No Rate Detected

Verify that hydraulic system is functioning. Adjust control valve settings as needed.

517303.13

Product 5 Rate—Calibration Required

Reference Operator’s Manual and calibrate system.

517303.15

Product 5 Rate—Rate Above Target

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517303.17

Product 5 Rate—Rate Below Target

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517303.18

Product 5 Rate—Volume Per Minute Below Minimum

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517303.31

Product 5 Rate—No RPM Speed

Verify that hydraulic system is functioning. Adjust control valve settings as needed.

517304.15

RPM 2—Above Maximum Threshold

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517304.17

RPM 2—Below Minimum Threshold

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517305.01

Product Pump 2—Pump Dry (PWM control valve)

Turn off master switch and verify that there is product within the tank.

517305.18

Product Pump 2—Pump Dry (servo control valve)

Turn off master switch and verify that there is product within the tank.

517306.01

Product Pump 3—Pump Dry (PWM control valve)

Turn off master switch and verify that there is product within the tank.

517306.18

Product Pump 3—Pump Dry (servo control valve)

Turn off master switch and verify that there is product within the tank.

517307.01

Product Pump 4—Pump Dry (PWM control valve)

Turn off master switch and verify that there is product within the tank.

517307.18

Product Pump 4—Pump Dry (servo control valve)

Turn off master switch and verify that there is product within the tank.

517308.01

Product Pump 5—Pump Dry (PWM control valve)

Turn off master switch and verify that there is product within the tank.

517308.18

Product Pump 5—Pump Dry (servo control valve)

Turn off master switch and verify that there is product within the tank.

517309.31

Product Bin/Tank 1—Empty

Turn off master switch and verify that there is product within the bin or tank.

517310.31

Product Bin/Tank 2—Empty

Turn off master switch and verify that there is product within the bin or tank.

517311.31

Product Bin/Tank 3—Empty

Turn off master switch and verify that there is product within the bin or tank.

517312.31

Product Bin/Tank 4—Empty

Turn off master switch and verify that there is product within the bin or tank.

517313.31

Product Bin/Tank 5—Empty

Turn off master switch and verify that there is product within the bin or tank.

517314.17

Product Bin/Tank 1—Low

Turn off master switch and verify that there is product within the bin or tank.

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517315.17

Product Bin/Tank 2—Low

Turn off master switch and verify that there is product within the bin or tank.

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517316.17

Product Bin/Tank 3—Low

Turn off master switch and verify that there is product within the bin or tank.

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517317.17

Product Bin/Tank 4—Low

Turn off master switch and verify that there is product within the bin or tank.

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517318.17

Product Bin/Tank 5—Low

Turn off master switch and verify that there is product within the bin or tank.

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517319.1

Product 1 Shaft Sensor

Turn off master switch and verify that there is product within the bin or tank.

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517320.1

Product 2 Shaft Sensor

Turn off master switch and verify that there is product within the bin or tank.

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517321.1

Product 3 Shaft Sensor

Turn off master switch and verify that there is product within the bin or tank.

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517322.1

Product 4 Shaft Sensor

Turn off master switch and verify that there is product within the bin or tank.

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517323.1

Product 5 Shaft Sensor

Turn off master switch and verify that there is product within the bin or tank.

Check settings within Alarms tab and adjust as needed.

Select Menu button > John Deere Rate Controller 2000 button > Setup softkey > Alarms tab.

517324.01

Product 1 Dual Encoder

The rate difference between the left and right encoder has exceeded the allowed tolerance.

(Reference Operator’s Manual and calibrate system.)

517325.01

Product 2 Dual Encoder

The rate difference between the left and right encoder has exceeded the allowed tolerance.

(Reference Operator’s Manual and calibrate system.)

517326.01

Product 3 Dual Encoder

The rate difference between the left and right encoder has exceeded the allowed tolerance.

(Reference Operator’s Manual and calibrate system.)

517327.01

Product 4 Dual Encoder

The rate difference between the left and right encoder has exceeded the allowed tolerance.

(Reference Operator’s Manual and calibrate system.)

517328.01

Product 5 Dual Encoder

The rate difference between the left and right encoder has exceeded the allowed tolerance.

(Reference Operator’s Manual and calibrate system.)

523350.08

Implement Height Switch Malfunction

Verify that implement is functioning properly.


AccuFlow HP is a trademark of Raven Industries Inc.

AE77568,00004A6-19-20190321