Diagnostic LEDs

PC22411
PC22411-UN-04APR16

A - A LED

B - B LED

C - C LED

D - Power LED


LED

Color

Blinks Per Second

Description

Power

Green

Solid state

Electronic control unit (ECU) powered

A

None

Solid state

Microprocessor is not powered

Any

Solid state

Microprocessor has stopped updating LED status

Yellow

1

Boot hold mode

Red

5

Microprocessor is programming

Red

1

ISOBUS is offline

White

1

Virtual terminal (VT) is offline

Purple

1

Loopback test mode is enabled

Green

1

VT and system are normal

B

Red

Solid state

Field programmable gate array (FPGA) is not running

Red

1

Low voltage power lost

Blue

1

Signal is present on one or more rate sensors

Yellow

1

Diagnostic trouble codes (DTCs) are active

White

1

System voltage is below 11.5 V

Purple

1

System voltage is above 16 V

Blue

Solid state

One or more product switches have been set to On

Purple

Solid state

Signal is present on one or more RPM sensors

Green

Solid state

All product switches have been set to Off

Red

Solid state

(Loopback test mode only)

Loopback subtest failed in current test sequence

Yellow

Solid state

(Loopback test mode only)

Loopback subtest failed in the previous sequence

Green

Solid state

(Loopback test mode only)

No loopback subtests have failed

C

Red

Solid state

FPGA is not running

Green

1

Auxiliary CAN channel is active

Red

1

Auxiliary CAN channel was active and is now offline

Green

Solid state

LED C is functional and there are no other LED C states to report

Purple

Solid state

Loopback test is in progress

AE77568,00004AB-19-20190321