Activate System

PC22413-UN-05APR16
A - Ground Speed
B - Master Switch Indicator
C - Height Switch Indicator
D - System Enable / Disable Toggle
Requirements to activate system:
-
Machine ground speed (A) is greater than 0.8 km/h (0.5 mph).
-
Master switch (B) is on.
-
If equipped, implement height switch (C) is engaged.
-
System Toggle (D) enabled. If operating multiple products, enable
System Toggle on each product run page desired for operation.
Orange Master Switch
If one or more requirements are not met, system does not apply
product. If all requirements are met and the master switch turns orange,
cycle the master foot switch to get out of hold state.
|
|
HC94949,0000C9D-19-20171220
|
|