Quick Start

PC22430-UN-05APR16
A - Quick Start Button
B - Section Status Indicators
C - Target Rate
D - Countdown Indicator
Quick Start is not available for any NH3 configuration.
Quick Start button (A) enables after activating system for a
product. If operating multiple products, select desired products and
enable system, and then select Quick Start button. This activates
all enabled products on the profile. Selecting Quick Start button
turns on all sections (B) only for selected product and applies product
at target rate (C).
When selected, Quick Start overrides Section Control and machine
speed threshold for the selected product for 15 seconds at a simulated
3 mph. A countdown indicator (D) appears when selected. Select Quick
Start button at any time during countdown to reset counter back to
15 seconds.
Use Quick Start to prime system when:
-
Entering a field.
-
Starting in a field corner.
-
Performing calibration or diagnostic tests.
|
|
HC94949,0000C9E-19-20171220
|
|