Data Cleanup
If the user interface does not show up anymore or if it does
not show up correctly, the data cleanup function removes the control
unit user interface files from the display. The cleanup forces the
control unit to send its data to the display again after a restart.
GreenStar 3 2630
Display

PC13663CC-19-24OCT13
Data Cleanup
A - Controllers Checkbox
B - Begin Cleanup Button
-
Select Menu button.
-
Select Message Center button.
-
Select Cleanup softkey.
-
Select the checkbox (A) for the data to be removed.
-
Select the Begin Cleanup button (B).
After a restart, the control unit will display a bar graph in
the main menu until the user interface is reloaded.
Generation 4 Display

PC16682-UN-18MAR13
ISOBUS VT
View the ISOBUS control unit in Status Center, and follow troubleshooting
steps for the status indicated. For more information, view ISOBUS
control units in Diagnostic Center.
If the interface still does not display correctly:
-
Select settings at the top of ISOBUS VT application.
-
Select Clean Up ISOBUS VT in advanced settings to clear stored
ISOBUS control unit user interface files.
The user interface is reloaded the next time the control unit
is connected.
|
GreenStar is a trademark of Deere
& Company
|
HC94949,0000CA5-19-20171213
|
|