To start the setup wizard, select the best-fit application type
and follow instructions up to the Setup Section Groups page.
(Reference Setup Overview for more information.)
-
For NH3 applications, the first six section drivers can
only be assigned to NH3 section valves. The second section group starts
at section driver seven or higher.
If configuring:
-
Select the Shared Section Drivers option form the drop-down
menu (A).
-
Yes, all products share same section configuration and wiring.
-
No, products will not share the same configuration and wiring.
-
Select the Next Page button (B).
-

PC22657-UN-02JUN16
A - Number of Sections Drop-Down Menu
B - Granular Product Sections Power to Apply Checkbox
C - Master Clutch Checkbox
D - Next Page Button
Select the Number of Section Groups from the drop-down menu
(A). For example, if setting up an air cart with two dry products
sharing the same section group with two sections and a liquid product
with its own section group with four sections. The total number of
section groups is two.
-
Select all that apply:
-
Granular Product Sections Power to Apply checkbox (B)—Select
for the control unit to provide power to the section signal wire when
the section is on. Deselect for the control unit to provide power
to the section signal wire when the section is off.
-
Master Clutch checkbox (C)—Select to enable the master signal
(air carts only).
-
Select Next Page button (D).
-
Note how your product harness is wired before identifying
the associate drivers. Section group 1 (A) valve starts on Starting
Section Driver 1 (B) and has four sections (C). Section Group 2 (D)
is wired to start on Driver 7, which must be identified as the starting
driver. Section Group 2 has 2 sections.

PC25098-UN-07DEC17
A - Section Group 1
B - Starting Section Driver
C - Number of Sections
D - Section Group 2
E - Next Page Button
If configuring products that requires multiple sections,
read the message and select the Next Page button (E).
-

PC22661-UN-18MAY16
A - Starting Section Driver
B - Number of Sections
C - Equal Section Width Checkboxes
D - Next Page Button
For NH3 applications or if fitting up harnesses already pinned
out to 37-pin connectors (for example replacing two GreenStar Rate
Controllers), drivers have to be skipped in order for product 2 sections
to line up with the harnessing.
-
NH3 application—The first six section drivers can only be assigned
to the first section group. The second section group must start at
section driver seven or higher.
-
37-Pin connectors—The second section group must start at section
driver eleven or higher as the first products 37 pin product harness
is claiming sections 1 to 10.
Enter the Starting Section Driver (A) and Number of Sections
(B) for each section group. Skip any unused section drivers. Product
harness wiring to the section valves or clutches determine the starting
section drivers.
(Reference Sections for more information on maximum number of
available sections.)
(Reference harnessing Installation Instructions or schematics
for more information.)
-
If applicable, select the Equal Section Width checkboxes (C).
-
Select the Next Page button (D). If all products share the same
section drivers, skip to step 12.
-

PC22667-UN-19MAY16
A - Product 1 Section Group Drop-Down Menu
B - Product 2 Section Group Drop-Down Menu
C - Product 3 Section Group Drop-Down Menu
D - Select Next Page Button
For each product, select the Section Group from the drop-down
menus (A—C).
-
Select the Next Page button (D).
-

PC22668-UN-19MAY16
A - Group 1, Section 1 Width
B - Group 1, Section 2 Width
C - Group 1, Section 3 Width
D - Group 1, Section 4 Width
E - Group 1, Section 5 Width
F - Group 2, Section 7 Width
G - Group 2, Section 8 Width
H - Next Page Button
Total width of all sections must be equal to the total Section
Group width. If Equal Width Sections was selected, Section Group width
is evenly divided by the number of sections.
Enter the width for each section (A—G).
-
Select the Next Page button (H).
-

PC25053-UN-28NOV17
A - Previous Page Button
B - Next Page Button
Graphic displays each section width and output driver that
controls each section valve. Verify that implement wiring is correct.
Section Group width and section widths may only be edited in the setup
wizard. If needed, select the Previous Page button (A) to make corrections.
Review the Setup Sections and select the Next Page button (B).
-
Continue the rest of the setup wizard for the selected configuration.