Inputs Table—Single Product
Enabling optional features, such as fence rows nozzles
and agitators, reduces number of section controls. (Reference
Sections in System Overview section.)
|
Input Number
|
Sprayer and Liquid Fertilizer Tool
|
NH3 Tool
|
|
1
|
Flow meter signal
|
Flow meter signal
|
|
2
|
Fill flow meter signal
|
Master valve status
|
|
3
|
|
|
|
4
|
|
|
|
5
|
|
|
|
6
|
|
Valve status 4
|
|
7
|
|
Valve status 5
|
|
8
|
|
Valve status 3
|
|
9
|
|
Valve power 1 sense
|
|
10
|
|
|
|
11
|
|
Valve power 2 sense
|
|
12
|
|
|
|
13
|
|
Valve status 1
|
|
14
|
Pressure signal 1 (boom pressure)
|
Pressure signal 1 (NH3 outlet)
|
|
15
|
|
Valve status 2
|
|
16
|
Pressure signal 2 (sparge pressure)
|
Pressure signal 2 (NH3 inlet)
|
|
17
|
|
|
|
18
|
|
Pressure signal 3
|
|
19
|
|
Valve status 7
|
|
20
|
|
Valve status 8
|
|
21
|
|
|
|
22
|
|
|
|
23
|
|
Valve status 6
|
|
24
|
Pump RPM signal
|
Pump RPM signal
|
|
25
|
Master Switch
|
Master Switch
|
|
26
|
Implement Height Switch
|
Implement Height Switch
|
|
27
|
|
|
|
28
|
|
Valve status 9
|
|
29
|
|
Valve status 10
|
|
|
RW00482,0000062-19-20171213
|
|