Set Up NH3+ Boost Pump
It is recommended to select Duty Cycle as a data field
to display when the boost pump is present. (For more
information on changing display settings, reference Adjust Settings.)
The Raven AccuFlow
HP Plus is controlled based on flow. The John Deere Rate
Controller 2000 is only able to control one fast valve when utilizing
an NH3 AccuFlow HP™ Plus configuration. Use a PWM in conjunction with
a fast control valve to control the AccuFlow HP™ Plus boost pump.
NH3 AccuFlow HP™ Plus configuration requires two pressure sensors:
-
Sensor 1 on the gauge tree.
-
Sensor 2 on the pump inlet.
Recommend starting settings:
-
Coil Frequency: 122
-
High limit: 85
-
Low limit: 20
-
Response Rate: 70
-
Control Deadband: 3
|
AccuFlow HP is a trademark of Raven Industries Inc.
|
RW00482,00001AC-19-20171220
|
|