Calibrate Pressure Sensor

To measure boom pressure, calibrate the pressure sensor.

  1. PC22295
    PC22295-UN-21MAR16

    John Deere Rate Controller 2000 Button

    Select the John Deere Rate Controller 2000 button.



  2. PC22296
    PC22296-UN-21MAR16

    Setup Softkey

    Select the Setup softkey.



  3. PC22378
    PC22378-UN-31MAR16

    A - Settings Tab

    B - Pressure Sensor Setup Button

    Select the Settings tab (A).



  4. Select the Pressure Sensor Setup button (B).

  5. PC22379
    PC22379-UN-31MAR16

    Calibrate Pressure Sensor Button

    Select the Calibrate Pressure Sensor button.



  6. PC22380
    PC22380-UN-31MAR16

    Pressure Sensor Drop-Down Menu

    Select the sensor to calibrate from the Pressure Sensor drop-down menu.



  7. PC22382
    PC22382-UN-31MAR16

    Voltage-based Calibration Button

    PC22381
    PC22381-UN-31MAR16

    Operation-based Calibration Button

    Select either the Voltage-based Calibration button or the Operation-based Calibration button.



Use the Voltage-based Calibration when the pressure sensor slope is known.

Operation-based calibration is only available when the system is configured for a single liquid product.

To use Operation-based Calibration, two calibration points must be determined since the slope is unknown. The John Deere Rate Controller 2000 automatically measures the voltage at zero pressure. The second calibration point is measured at an operator desired pressure.

PC22383
PC22383-UN-31MAR16

A - Voltage Slope

B - Accept Button

Voltage-based Calibration

The system requires zero pressure when entering the slope for the pressure sensor setup. Zero-volt sensors can be unplugged to zero the pressure sensor reading. One- to five-volt sensors require the pressure be relieved before entering the slope value.

  1. Verify with the sensor manufacturer that sensor can accept 12 V power.

    Ensure that sensor has 12 V power supply.

  2. For Raven pressure sensors with a 12 V power supply, slope is 16 mV/psi.

    Enter the slope (A) from the pressure sensor manufacturer.

  3. Select the Accept button (B).

PC22385
PC22385-UN-31MAR16

A - Next Page Button

Operation-based Calibration

Operation-based calibration is only available in the single product configurations.

  1. Set the pump to the normal operating speed.

  2. Turn on the master switch.

  3. Select the Next Page button (A).

  4. PC22384
    PC22384-UN-31MAR16

    A - Sections

    B - Fence Row Nozzle

    C - Next Page button

    To spray during calibration, enable sections (A) and if needed, fence row nozzles (B).



  5. Select the Next Page button (C).

  6. PC22386
    PC22386-UN-31MAR16

    A - Minus (-) Button

    B - Plus (+) Button

    C - Sensor Pressure

    D - Accept Button

    To set the desired boom pressure, use the + / - buttons (A and B). The new pressure must increase pressure sensor voltage by at least 0.25 V.



  7. Enter the pressure (C) from the implement pressure gauge.

  8. To complete calibration, select the Accept button (D).