Calibrate Pressure Sensor
To measure boom pressure, calibrate the pressure sensor.
-

PC22295-UN-21MAR16
John Deere Rate Controller 2000 Button
Select the John Deere Rate Controller 2000 button.
-

PC22296-UN-21MAR16
Setup Softkey
Select the Setup softkey.
-

PC22378-UN-31MAR16
A - Settings Tab
B - Pressure Sensor Setup Button
Select the Settings tab (A).
-
Select the Pressure Sensor Setup button (B).
-

PC22379-UN-31MAR16
Calibrate Pressure Sensor Button
Select the Calibrate Pressure Sensor button.
-

PC22380-UN-31MAR16
Pressure Sensor Drop-Down Menu
Select the sensor to calibrate from the Pressure Sensor drop-down
menu.
-

PC22382-UN-31MAR16
Voltage-based Calibration Button

PC22381-UN-31MAR16
Operation-based Calibration Button
Select either the Voltage-based Calibration button or the
Operation-based Calibration button.
Use the Voltage-based Calibration when the pressure sensor slope
is known.
Operation-based calibration is only available when the
system is configured for a single liquid product.
To use Operation-based Calibration, two calibration points must
be determined since the slope is unknown. The John Deere Rate Controller
2000 automatically measures the voltage at zero pressure. The second
calibration point is measured at an operator desired pressure.

PC22383-UN-31MAR16
A - Voltage Slope
B - Accept Button
Voltage-based Calibration
The system requires zero pressure when entering the slope for
the pressure sensor setup. Zero-volt sensors can be unplugged to zero
the pressure sensor reading. One- to five-volt sensors require the
pressure be relieved before entering the slope value.
-
Verify with the sensor manufacturer that sensor can
accept 12 V power.
Ensure that sensor has 12 V power supply.
-
For Raven pressure sensors with a 12 V power supply, slope
is 16 mV/psi.
Enter the slope (A) from the pressure sensor manufacturer.
-
Select the Accept button (B).

PC22385-UN-31MAR16
A - Next Page Button
Operation-based Calibration
Operation-based calibration is only available in the single
product configurations.
-
Set the pump to the normal operating speed.
-
Turn on the master switch.
-
Select the Next Page button (A).
-

PC22384-UN-31MAR16
A - Sections
B - Fence Row Nozzle
C - Next Page button
To spray during calibration, enable sections (A) and if needed,
fence row nozzles (B).
-
Select the Next Page button (C).
-

PC22386-UN-31MAR16
A - Minus (-) Button
B - Plus (+) Button
C - Sensor Pressure
D - Accept Button
To set the desired boom pressure, use the + / - buttons (A
and B). The new pressure must increase pressure sensor voltage by
at least 0.25 V.
-
Enter the pressure (C) from the implement pressure gauge.
-
To complete calibration, select the Accept button (D).
|
|