Component Overview and Compatibility
Valve power and ground pins are not reverse-voltage
protected. To prevent damaging the control unit, take precautions
to prevent pins from being connected backwards.
The following component configurations are compatible with the
John Deere Rate Controller 2000.
(Reference Main Harness [47-Pin Connector] Table in Specifications
section for more information.)
Section Valves
-
Section valves with 3-wire single pole single throw (SPST).
For the rate control setup, a valve with a solenoid-like operation
is considered a 3-wire valve. There is one signal wire controlling
operation of the valve. When signal voltage is high (12 V), valve
is opened. When signal voltage is low (0 V), valve closes. This is
sometimes referred to as an SPST valve. There may be configurations
where a valve with this operation only has two wires, a signal wire
and a ground wire.
-
Use valve power and valve ground for all section valves. If
valve power and valve ground are not connected, section valves do
not open or close.
-
Split section valves evenly among available valve power and
ground pins to disperse electrical load evenly through those terminals.
-
Section valves with 2-wire double pole double throw (DPDT).
Valve is not compatible on NH3 systems.
For the rate control setup, a valve with reversing capabilities
is considered a 2-wire valve. This valve needs two drivers to control
its operation. When (+) signal voltage is high (12 V) and (-) signal
voltage is low (0 V), valve opens. Likewise, when (-) signal voltage
is high (12 V) and (+) signal voltage is low (0 V), valve closes.
When both signal voltages are low (0 V), the valve does not move.
This type of valve is sometimes referred to as a DPDT valve.
-
Section valves that require less than 2.5 A.
Raven Sidekick Pro™ ICD (ISO Client Device)
Compatibility
Raven Sidekick Pro™ ISO pumps are not compatible with
John Deere Rate Controller 2000.
John Deere Rate Controller 2000 is only compatible with the
Raven Sidekick Pro ICD direct injection system. Raven Sidekick Pro™ ICD
injects varying amounts of product into the main solution line of
the implement. This eliminates the need to mix chemicals in the main
tank.
John Deere Rate Controller 2000 supports up to four Raven ICD
direct injection pumps with a carrier. Total products must remain
under five.
When the direct injection pump is detected in the CAN bus, the
John Deere Rate Controller 2000 automatically populates the additional
product in the profile.
GreenStar 3 2630 Display can control a maximum of five products, but only
up to four products can be documented. John Deere 4640 Universal Display
and 4600 CommandCenter™ can control and document five products.
|
Sidekick Pro is a trademark of Raven Industries Inc.
GreenStar is a trademark of Deere & Company
|
RW00482,00006A0-19-20171220
|
|