Set Up Implement Height Indicator
Implement height switch is required for NH3 applications
and cannot be disabled.
Implement height indicator is optional for liquid fertilizer
tools (switch only) and air carts (switch or sensor). Implement height
indicator can be enabled, disabled, and set up without the setup wizard
for these applications.
-

PC22295-UN-21MAR16
John Deere Rate Controller 2000 Button
Select the John Deere Rate Controller 2000 button.
-

PC22296-UN-21MAR16
Setup Softkey
Select the Setup softkey.
-

PC22693-UN-25MAY16
A - Implement Tab
B - Height Indicator Checkbox
C - Height Setup Button
Select the Implement tab (A).
-
To enable, select the Implement Height Switch or Height Indicator
checkbox (B).
-
To change the type of the height indicator, select the Height
Setup button (C).
-

PC22694-UN-09JUN16

PC22695-UN-09JUN16
A - Height Indicator Drop-Down Menu
B - Current Voltage
C - New Set Point
D - Accept Button
Select Sensor or Switch from the Height Indicator drop-down
menu (A).
If Sensor is selected, lower implement to the ground and enter
the Current Voltage (B) into New Set Point (C).
-
Select the Accept button (D).
|
|
RW00482,00006AD-19-20171213
|
|