Adjust Settings

Settings tab allows the operator to change most settings after creating a profile with the setup wizard.

  1. PC22295
    PC22295-UN-21MAR16

    John Deere Rate Controller 2000 Button

    Select the John Deere Rate Controller 2000 button.



  2. PC22296
    PC22296-UN-21MAR16

    Setup Softkey

    Select the Setup softkey.



  3. PC22341
    PC22341-UN-06APR16

    A - Settings Tab

    Select the Settings tab (A).




Control Valve Setup Button

PC22436
PC22436-UN-06APR16

Control Valve Setup Button

  • Valve Response Rate
  • Control Deadband
  • Valve Delay
  • Valve Advance
  • Control Effort
  • PWM Setup

    (Reference Adjust Control Valve for more information.)

    • Coil Frequency
    • High Limit
    • Low Limit
    • PWM Standby
    • PWM Startup
  • Boost Pump Setup
    • Coil Frequency
    • High Limit
    • Low Limit
    • Valve Response Rate

Flow / Rate Sensor Setup Button

PC22437
PC22437-UN-06APR16

Flow / Rate Sensor Setup Button

  • Flowmeter Calibration
  • Flowmeter Pulse / Units
  • Tank Fill Flowmeter Calibration
  • Tank Fill Flowmeter Pulse / Units
  • Catch Test Calibration

    (Reference Calibrate Flowmeter—Catch Test for more information.)

  • Applied Product Calibration

    (Reference Calibrate Flowmeter—Applied Product for more information.)


Tank / Bin Setup Button

PC22438
PC22438-UN-06APR16

Tank / Bin Setup Button

  • Tank Capacity
  • Current Level
  • Low Tank Level
  • Low Tank Level Alarm
  • Low Bin Level Sensor
  • Bin Chaining Mode
  • Bin Chaining Order

(Reference Set Up Bin Chaining for more information.)


Display Settings Button

PC22439
PC22439-UN-06APR16

Display Settings Button

The four data fields selected display on the top half of the main run page. Softkey region may be configured to display the first three selected data fields for each product.

  • Data Fields Displayed
    • Actual Rate Per Area
    • Target Rate Per Area
    • Area Per Hour
    • Area Remaining on Current Tank Level
    • Traveling Speed
    • Pressure Sensor
    • Volume Remaining
    • Volume Per Time (Flow Rate)
    • Area
    • Volume Applied
    • Duty Cycle

It is recommended to select Duty Cycle as a data field to display when the boost pump is present.


Pressure Sensor Setup Button

PC22440
PC22440-UN-06APR16

Pressure Sensor Setup Button

  • Pressure Sensor 1—6
  • Calibrate Pressure Sensor
  • Pressure Alignment Setup

(Reference Calibrate Pressure Sensor for more information.)


Auxiliary Features Setup Button

PC22441
PC22441-UN-06APR16

Auxiliary Features Setup Button

  • RPM 1 Calibration Pulse / Rev
  • RPM 1 Low Limit
  • RPM 1 Low Limit Alarm
  • RPM 1 High Limit
  • RPM 1 Low Limit Alarm
  • RPM Sensor Assignment
  • Enable Agitator
  • Agitator Duty Cycle

Tiered Boom Setup Button

PC22442
PC22442-UN-06APR16

Tiered Boom Setup

  • Tier 1 Max Flow Rate
    • On a 2-tier system, both tiers are enabled once Tier 1 Max Flow Rate is achieved.
    • On a 3-tier system, the first tier is disabled and the second tier is enabled once Tier 1 Max Flow Rate is achieved.
  • Tier 2 Max Flow Rate
    • On a 2-tier system, Tier 2 Max Flow Rate should be set to zero.
    • On a 3-tier system, both tiers are enabled once Tier 2 Max Flow Rate is achieved.
  • Percent Tier Disable
    • Percent Tier Disable is the percentage of volume per minute setting that causes system to disable higher tier.

RW00482,00006AE-19-20171220