Adjust Settings
Settings tab allows the operator to change most settings after
creating a profile with the setup wizard.
-

PC22295-UN-21MAR16
John Deere Rate Controller 2000 Button
Select the John Deere Rate Controller 2000 button.
-

PC22296-UN-21MAR16
Setup Softkey
Select the Setup softkey.
-

PC22341-UN-06APR16
A - Settings Tab
Select the Settings tab (A).
Control Valve Setup Button

PC22436-UN-06APR16
Control Valve Setup Button
Flow / Rate Sensor Setup Button

PC22437-UN-06APR16
Flow / Rate Sensor Setup Button
Tank / Bin Setup Button

PC22438-UN-06APR16
Tank / Bin Setup Button
-
Tank Capacity
-
Current Level
-
Low Tank Level
-
Low Tank Level Alarm
-
Low Bin Level Sensor
-
Bin Chaining Mode
-
Bin Chaining Order
(Reference Set Up Bin Chaining for more information.)
Display Settings Button

PC22439-UN-06APR16
Display Settings Button
The four data fields selected display on the top half
of the main run page. Softkey region may be configured to display
the first three selected data fields for each product.
-
Data Fields Displayed
-
Actual Rate Per Area
-
Target Rate Per Area
-
Area Per Hour
-
Area Remaining on Current Tank Level
-
Traveling Speed
-
Pressure Sensor
-
Volume Remaining
-
Volume Per Time (Flow Rate)
-
Area
-
Volume Applied
-
Duty Cycle
It is recommended to select Duty Cycle as a data field
to display when the boost pump is present.
Pressure Sensor Setup Button

PC22440-UN-06APR16
Pressure Sensor Setup Button
-
Pressure Sensor 1—6
-
Calibrate Pressure Sensor
-
Pressure Alignment Setup
(Reference Calibrate Pressure Sensor for more information.)
Auxiliary Features Setup Button

PC22441-UN-06APR16
Auxiliary Features Setup Button
-
RPM 1 Calibration Pulse / Rev
-
RPM 1 Low Limit
-
RPM 1 Low Limit Alarm
-
RPM 1 High Limit
-
RPM 1 Low Limit Alarm
-
RPM Sensor Assignment
-
Enable Agitator
-
Agitator Duty Cycle
Tiered Boom Setup Button

PC22442-UN-06APR16
Tiered Boom Setup
-
Tier 1 Max Flow Rate
-
On a 2-tier system, both tiers are enabled once Tier 1 Max Flow
Rate is achieved.
-
On a 3-tier system, the first tier is disabled and the second
tier is enabled once Tier 1 Max Flow Rate is achieved.
-
Tier 2 Max Flow Rate
-
On a 2-tier system, Tier 2 Max Flow Rate should be set to zero.
-
On a 3-tier system, both tiers are enabled once Tier 2 Max Flow
Rate is achieved.
-
Percent Tier Disable
-
Percent Tier Disable is the percentage of volume per minute
setting that causes system to disable higher tier.
|
|