Always fill solution tank with clean water before
performing a calibration test.
Ensure that control valve and rate sensor are configured
before performing a calibration test.
Catch Test allows operator to collect product from up to seven
samples and enter exact amounts collected to calibrate flowmeter.
Place containers (such as calibration containers) under the nozzles
to capture the product sprayed during test. If all the nozzles require
testing, repeat the Flowmeter Calibration as many times as needed.
By measuring these samples and entering the values into system, an
accurate flowmeter calibration value is determined.
-

PC22295-UN-21MAR16
John Deere Rate Controller 2000 Button
Select the John Deere Rate Controller 2000 button.
-

PC22296-UN-21MAR16
Setup Softkey
Select the Setup softkey.
-

PC22369-UN-31MAR16
A - Settings Tab
B - Flow / Rate Sensor Setup Button
Select the Settings tab (A).
-
Select the Flow / Rate Sensor Setup button (B).
-

PC22714-UN-01JUN16
A - Product Drop-Down Menu
B - Catch Test Calibration Button
Select the Product from the drop-down menu (A).
-
Select the Catch Test Calibration button (B).
-

PC22713-UN-01JUN16
A - Sections
B - Calibrate Rate Sensor Button
If the system is not primed, charge the tank or bin before
calibration.(Reference Tank / Bin Charging for more information.)
In multiple product configurations, only the sections assigned
to the selected product may be selected. Repeat Flowmeter Calibration
as many times as needed for all product and sections that requires
testing.
Enable the sections (A) to apply.
-
Select the Calibrate Rate Sensor (B).
-

PC22371-UN-31MAR16
A - Number of Nozzles that will Spray
B - Test Speed
C - Rate
D - Volume to Dispense per Nozzle
E - Next Page Button
Enter conditions that are comparable to normal operation.
Larger dispense volumes result in longer, but more accurate, calibration
tests.
Enter the calibration test parameters (A—D).
-
Select the Next Page button (E).
-

PC22372-UN-31MAR16
A - Start button
Turn on the master switch.
-
To begin the test, select the Start button (A).
-

PC22373-UN-08APR16
A - Sample 1
B - Sample 2
C - Sample 3
D - Sample 4
E - Sample 5
F - Sample 6
G - Sample 7
H - New Calibration Value
I - Take Another Sample Button
J - Accept Button
Turn master switch off at any time to cancel the test.If fewer than seven samples are collected, leave remaining values
set to 0.
Enter the sample volumes (A—G). New Calibration Value (H) is
calculated as the samples are entered.
-
Select Take Another Sample (I) if necessary.
-
Select the Accept button (J).