Calibrate Flowmeter—Liquid Catch Test

Always fill solution tank with clean water before performing a calibration test.

Ensure that control valve and rate sensor are configured before performing a calibration test.

Catch Test allows operator to collect product from up to seven samples and enter exact amounts collected to calibrate flowmeter. Place containers (such as calibration containers) under the nozzles to capture the product sprayed during test. If all the nozzles require testing, repeat the Flowmeter Calibration as many times as needed. By measuring these samples and entering the values into system, an accurate flowmeter calibration value is determined.

  1. PC22295
    PC22295-UN-21MAR16

    John Deere Rate Controller 2000 Button

    Select the John Deere Rate Controller 2000 button.



  2. PC22296
    PC22296-UN-21MAR16

    Setup Softkey

    Select the Setup softkey.



  3. PC22369
    PC22369-UN-31MAR16

    A - Settings Tab

    B - Flow / Rate Sensor Setup Button

    Select the Settings tab (A).



  4. Select the Flow / Rate Sensor Setup button (B).

  5. PC22714
    PC22714-UN-01JUN16

    A - Product Drop-Down Menu

    B - Catch Test Calibration Button

    Select the Product from the drop-down menu (A).



  6. Select the Catch Test Calibration button (B).

  7. PC22713
    PC22713-UN-01JUN16

    A - Sections

    B - Calibrate Rate Sensor Button

    If the system is not primed, charge the tank or bin before calibration.

    (Reference Tank / Bin Charging for more information.)

    In multiple product configurations, only the sections assigned to the selected product may be selected. Repeat Flowmeter Calibration as many times as needed for all product and sections that requires testing.

    Enable the sections (A) to apply.



  8. Select the Calibrate Rate Sensor (B).

  9. PC22371
    PC22371-UN-31MAR16

    A - Number of Nozzles that will Spray

    B - Test Speed

    C - Rate

    D - Volume to Dispense per Nozzle

    E - Next Page Button

    Enter conditions that are comparable to normal operation. Larger dispense volumes result in longer, but more accurate, calibration tests.

    Enter the calibration test parameters (A—D).



  10. Select the Next Page button (E).

  11. PC22372
    PC22372-UN-31MAR16

    A - Start button

    Turn on the master switch.



  12. To begin the test, select the Start button (A).

  13. PC22373
    PC22373-UN-08APR16

    A - Sample 1

    B - Sample 2

    C - Sample 3

    D - Sample 4

    E - Sample 5

    F - Sample 6

    G - Sample 7

    H - New Calibration Value

    I - Take Another Sample Button

    J - Accept Button

    Turn master switch off at any time to cancel the test.

    If fewer than seven samples are collected, leave remaining values set to 0.

    Enter the sample volumes (A—G). New Calibration Value (H) is calculated as the samples are entered.



  14. Select Take Another Sample (I) if necessary.

  15. Select the Accept button (J).