Calibrate Rate Sensor—Applied Dry Product

Ensure that control valve and rate sensor are configured before performing a calibration test.

Applied product test allows operator to apply a known amount of product to calibrate the rate sensor. The actual amount applied is compared to the amount recorded by the control unit and that is used to adjust the calibration value.

  1. PC22295
    PC22295-UN-21MAR16

    John Deere Rate Controller 2000 Button

    Select the John Deere Rate Controller 2000 button.



  2. PC22296
    PC22296-UN-21MAR16

    Select the Setup softkey.



  3. PC22369
    PC22369-UN-31MAR16

    A - Settings Tab

    B - Flow / Rate Sensor Setup Button

    Select the Settings tab (A).



  4. Select the Flow / Rate Sensor Setup button (B).

  5. PC22377
    PC22377-UN-31MAR16

    Applied Product Calibration Button

    Select the Applied Product Calibration button.



  6. PC24162
    PC24162-UN-02MAY17

    A - Accept Button

    Select the Accept button (A).



  7. Turn on the master switch to apply product. While applying product, the operator can navigate away from the page and return after applying sufficient amount of product to complete the calibration.

    Apply product to field.

  8. PC22723
    PC22723-UN-02JUN16

    B - Stop Button

    After desired amount of product has been applied, select the Stop button (B).



  9. PC24163
    PC24163-UN-02MAY17

    Calibrate Rate Sensor Button

    Select the Calibrate Rate Sensor button.



  10. PC22724
    PC22724-UN-02JUN16

    A - Actual Amount Applied

    B - New Calibration Value

    C - Accept Button

    Enter the amount of product applied (A). New Calibration Value (B) is calculated after the amount is entered.



  11. Select the Accept button (C).