Flow control knob will not turn
|
Dirt build-up.
|
Clean dirt from flow control knob and shaft.
|
Remote cylinder rate-of-travel too fast or too slow
|
Incorrect flow control adjustment.
|
Adjust flow control.
|
Detent does not hold SCV lever or releases too soon
|
Detent selector in wrong position.
|
Turn selector to correct position.
|
|
Pressure restriction with some implements.
|
Reduce oil flow by changing flow control setting.
|
|
Flow control or detent setting incorrect.
|
Adjust flow control and/or detent setting.
|
SCV lever does not release
|
Detent selector not in automatic detent position.
|
Turn selector to correct position.
|
|
Built-in pressure leakage with some implements.
|
Increase oil flow by changing flow control setting.
|
|
Flow control or detent setting incorrect.
|
Adjust flow control and/or detent setting.
|