Direction of remote cylinder travel is reversed
Improper hose connections.
Reverse hose connections.
Hoses will not couple
Improper hose male tips.
Replace tip with ISO standard tips.
Remote cylinder will not lift load
Excessive load.
Reduce load.
Hoses not completely installed.
Attach hoses correctly.
Incorrect remote cylinder size.
Use correct size cylinder.
OUMX005,0001ABA -19-29SEP04-1/1