Symptom |
Problem |
Solution |
Implement will not operate at desired depth
|
Lift links too short.
|
Adjust lift links.
|
|
Lack of penetration.
|
See implement operator's manual.
|
|
Electro-hydraulic controls: draft sensor failed.
|
See your John Deere dealer.
|
|
Improper setting of hitch control stop.
|
Readjust position.
|
|
Improper setting of draft (mechanical) or load/depth (electro-hydraulic) control.
|
(See Rockshaft Controls in section 60.)
|
Insufficient or no hitch response to draft load
|
Front attachment of center link in upper holes.
|
Move center link attachment to lower bracket holes.
|
|
Mechanical controls: draft control lever in OFF position.
|
Move lever to desired position.
|
|
Electro-hydraulic controls: load/depth control in position 1.
|
Turn load/depth mix control to higher setting.
|
|
Lift links too short.
|
Adjust lift links.
|
|
Lack of penetration.
|
See implement operator's manual.
|
|
Electro-hydraulic controls: system is reset.
|
Enable system.
|
|
Rate-of-drop too slow.
|
Adjust rate-of-drop.
|
Hitch too responsive
|
Front attachment on center link in lower bracket holes.
|
Move center link attachment to upper bracket holes.
|
|
Mechanical controls: improper draft control setting.
|
Adjust.
|
|
Electro-hydraulic controls: load/depth mix control not correctly set.
|
Turn load/depth mix control to lower setting.
|
Hitch drops too fast
|
Rate-of-drop set too fast.
|
Adjust rate-of-drop.
|
Mechanical controls: rockshaft levers "drift", levers too loose
|
Friction disks are loose.
|
Adjust rockshaft control lever friction. See your John Deere dealer.
|