Adjusting Flow Control-Deluxe SCV and Three-Function Mid-Mount Valve-If Equipped

causym CAUTION: Excessive operating speed may cause injury or machine damage.

Decrease flow rate if hydraulic oil overheats, remote cylinder moves too quickly or if hydraulic motor turns too fast.

Flow control adjustment only affects the number I section of rear SCV and the electro-hydraulic (grapple) section of the three-function mid-mount control valve. Other valve sections are not affected by this adjustment.

To adjust flow rate and operating speed, loosen lock nut (A) and turn flow control knob (B):

  • To increase flow rate and speed, turn COUNTERCLOCKWISE (Rabbit).
  • To decrease flow rate and speed, turn CLOCKWISE (Turtle).

NOTE: Rear SCV: If detent kicks out before end of cycle, use SCV I and adjust flow control.

LV12596

Deluxe SCV

LV12597

Three-Function Valve


A-Lock Nut
B-Flow Control Knob

OUO1023,00028C9 -19-18APR06-1/1