Operating Control Levers
Extend and Retract Cylinders:
With hoses properly connected to couplers, pull lever back to extend remote cylinder or push forward to retract.
-
When selector knob is set to
No Detent (Loader)
position, lever returns to neutral when released.
-
When selector knob is set to
Automatic Detent (Cylinder)
position, lever automatically returns to neutral when cylinder reaches the end of stroke.
-
When selector knob is set to
Continuous Detent (Motor)
position, lever must be manually returned to neutral.
With lever in neutral, remote cylinder is hydraulically locked in position.
Float Position:
Push lever forward, through retract, into detent to operate "float" feature. "Float" operation allows cylinder to extend and retract freely, such as when an implement follows ground contour. Manually return lever to neutral when "float" is no longer required.
Hydraulic Motor Operations
See Using Rear SCV to Operate Hydraulic Motor in this section.
|
Straddle Mount and Hi-Crop
IOOS Shown; Cab Similar
A-SCV I Lever
B-SCV II Lever
C-SCV III Lever
|