ROPS Maintenance or Replacement (OOS)

P10072
P10072-UN-05FEB01

A - Mounting Bolt (8 used)

B - Flat Washer (8 used)


Service Interval—250 Hours

CAUTION: Make certain all parts are installed correctly if ROPS is loosened or removed for any reason. Tighten mounting bolts to proper torque.

The protection offered by ROPS will be impaired if ROPS is subjected to structural damage, as in an overturn incident, or is in any way altered by welding, bending, drilling, or cutting. A damaged ROPS should be replaced, not reused. Any alteration to the ROPS must be approved by the manufacturer.

Check torque values on all ROPS mounting hardware.

ItemMeasurementSpecification
ROPS Mounting BoltsTorque610 N˙m (450 lb-ft)

NOTE: When installation of equipment on a machine requires loosening or removing Roll Over Protective Structure (ROPS), mounting bolts (A) with washers (B) should be tightened to specification upon re-installation.