Requirements for E-SCVs

Before transferring control to implement, prepare implement as indicated in implement Operator's Manual. Transfer control using AutoTrac resume switch or TIA resume softkey as presented in the implement Operator's Manual.

The following preconditions have to be met before transferring implement control.

  • Operator sitting on seat.
  • SCVs are functional.
  • SCV control levers in neutral position.
  • SCVs are not locked (transport lock).
  • SCV flow limit set by operator

NOTE: Using tractor's CommandCenter, operator sets SCV flow limit which cannot be exceeded by implement.

While operating, implement has the ability to:

  • Control SCVs during operations.
  • Change SCV flow rate up to operator set limit.

To withdraw control:

  • Actuate specific SCV lever.
  • Lock SCVs (transport lock).
  • Actuate remote control switch on the fender.

NOTE: Unless the implement is authorized to adjust SCV flow when the tractor is stationary, the tractor will prevent SCV flow adjustments when stationary. The implement is however, allowed to stop oil flow.