Implement Connection Example 2—Motor Application Using
Motor Case Drain—Less Hitch—Standard Hydraulics

RXA0126115-UN-03MAY12
Implement Connection Example 2
A - Power Beyond Pressure Line
B - Power Beyond Return Line
C - Load Sense Line
D - Control Valve
E - Vacuum Motor
F - Raise/Lower Cylinder
G - Motor Seal Drain Line
H - Fan
I - Marker
J - Fold
K - Load Sense Port
L - Extend Coupler Line
M - Retract Coupler Line
N - Controlled Flow Line
O - Hose Tip
NOTE: For Ag high flow, it is recommended that the hydraulic
motor be connected to the top SCV’s (45cc high flow pump). Not recommended for high flow scraper hydraulics.
In this motor application (E) is being operated from power beyond
which requires a load sense connection (C) to signal hydraulic pump
for operation.
The second motor (H) is equipped with motor case drain line
(G). Pressure oil comes from the retract port on the SCV and return
oil is routed to the extend port. When motor return oil is routed
to an SCV, a special return hose tip (O) with check valve is required
to prevent high pressure oil from moving back toward the motor and
possibly damaging the seals. When the motor is shut off, the SCV lever
is moved to float position to allow motor to coast to a stop. Moving
lever to neutral will cause motor to stop abruptly and may damage
seals.
|
|
RW29387,0000569-19-20120502
|
|