Using Implement Requiring Large Volumes of Oil

CAUTION: Do not add hydraulic oil to reservoir with engine running, which can result in overflowing the hydraulic reservoir.

NOTE: Do not overfill the hydraulic reservoir.

Lower the implement to have maximum oil in the reservoir during the checking procedure.

Cycle all implement cylinders after starting tractor.

Check the hydraulic oil reservoir sight gauge level. (See CHECK TRANSMISSION-HYDRAULIC-AXLE OIL LEVEL in the Lubrication and Maintenance Section.)

Lower implement to ground to return the most oil to the reservoir.

Recheck oil level when implement is removed.

Add oil if required.

Drain any oil excess from hydraulic reservoir using reservoir drain valve or plug.

RW29387,0000573-19-20101109