Requirements for E-SCVs

Before transferring control to implement, prepare implement as indicated in implement Operator's Manual. Transfer control using AutoTrac™ resume switch or TIA resume softkey as presented in Operating Tractor Implement Automation of this section.

The following preconditions have to be met before transferring implement control.

  • Operator sitting on seat.
  • SCVs are functional.
  • SCV control levers in neutral position.
  • SCVs are not locked (transport lock).
  • SCV flow limit set by operator

NOTE: Using tractor's CommandCenter, operator sets SCV flow limit which cannot be exceeded by implement.

While operating, implement has the ability to;

  • Control SCVs during operations.
  • Change SCV flow rate up to operator set limit.

To withdraw control:

  • Actuate corresponding SCV lever.
  • Lock SCVs (transport lock).
  • Actuate remote control switch on the fender.

NOTE: Unless authorized tractor will prevent SCV flow adjustments when stationary, It is however, allowed to stop oil flow.


AutoTrac is a trademark of Deere & Company

RW29387,00007EE-19-20101019