Requirements for E-SCVs
Before transferring control to implement, prepare implement
as indicated in implement Operator's Manual. Transfer control using AutoTrac resume
switch or TIA resume softkey as presented in Operating Tractor Implement
Automation of this section.
The following preconditions have to be met before transferring
implement control.
-
Operator sitting on seat.
-
SCVs are functional.
-
SCV control levers in neutral position.
-
SCVs are not locked (transport lock).
-
SCV flow limit set by operator
NOTE: Using tractor's CommandCenter, operator sets SCV flow
limit which cannot be exceeded by implement.
While operating, implement has the ability to;
-
Control SCVs during operations.
-
Change SCV flow rate up to operator set limit.
To withdraw control:
-
Actuate corresponding SCV lever.
-
Lock SCVs (transport lock).
-
Actuate remote control switch on the fender.
NOTE: Unless authorized tractor will prevent SCV flow adjustments
when stationary, It is however, allowed to stop oil flow.
|