Aborting Powershift Transmission Calibration
The PTP shall abort calibration, and shall make no changes to
stored calibration values in any of the following cases:
-
If significant tractor motion is detected
-
If the address number is incremented or decremented by the operator
-
In the event of any calibration fault occurrence
-
If the shift lever is moved out of gear
-
If the engine speed moves above or below the limits required
for calibration
If calibration aborts, all preexisting calibration numbers remain
stored and in effect, whether they are the default values or values
determined in a previous calibration. Calibration cannot be restarted
from the point at which it was aborted.
Calibration shall be restarted only from the beginning. No
new calibration numbers shall be stored until the entire calibration
process completes, at which point the newly determined values for
all clutches are stored.
|
|