SCV CAN Controller (SCC) Diagnostic Trouble Codes

Although the diagnostic codes listed below are not a complete list of the diagnostic trouble codes, they do reflect codes which may be observed while operating the tractor and have corrective action that the operator can correct. Many codes which appear may be corrected simply by cycling key switch or by following the solution on the CommandCenter™ page, then cycling tractor power.

If corrective action cannot be taken after cycling power to the tractor or if there are any questions, contact your John Deere™ dealer.

SCV CAN Controller (SCC) Diagnostic Trouble Codes

Diagnostic Trouble Code

System

Solution

SCC 000158.04

Hydraulic System

SCV control unit supply voltage low. Reduce electrical load or increase engine RPM to attempt vehicle recovery. 

SCC 000168.04

Hydraulic System

SCV control unit voltage low. Reduce electrical load or increase engine RPM. Power down and check fuse. Restart engine to attempt vehicle recovery. 

SCC 002602.01

Hydraulic System

Hydraulic oil level low. Check oil level according to Operator's Manual procedure. 

SCC 002602.18

Hydraulic System

Hydraulic oil level low. Increase engine rpm and limit hydraulic use to allow clean oil reservoir to refill. Check oil level according to Operator's manual. 

SCC 522164.31

Hydraulic System

Operator out of seat with SCV X on. Return to seated position. 

SCC 522165.31

Hydraulic System

Operator out of seat with SCV IX on. Return to seated position. 

SCC 522166.31

Hydraulic System

Operator out of seat with SCV VIII on. Return to seated position. 

SCC 522167.31

Hydraulic System

Operator out of seat with SCV VII on. Return to seated position. 

SCC 523783.07

Hydraulic System

SCV remote position control system stalled. Increase SCV max flow rate. 

SCC 523783.07

Hydraulic System

SCV remote position control system stalled. Increase SCV max flow rate. 

SCC 523784.07

Hydraulic System

SCV remote position control system stalled. Increase SCV max flow rate. 

SCC 523785.07

Hydraulic System

SCV remote position control system stalled. Increase SCV max flow rate. 

SCC 523786.07

Hydraulic System

SCV remote position control system stalled. Increase SCV max flow rate. 

SCC 523788.02

Hydraulic System

Hydraulic option connector changed from start up. Reference Hydraulic Option Configuration procedure in Operator's Manual. 

SCC 523788.14

Hydraulic System

Hydraulic option connector changed from start up. Reference Hydraulic Option Configuration procedure in Operator's Manual. 

SCC 523788.31

Hydraulic System

Hydraulic option connector fault. Reference Hydraulic Option Configuration procedure in Operator's Manual. 

SCC 523942.31

Hydraulic System

Operator out of seat with SCV VI on. Return to seated position. 

SCC 523943.31

Hydraulic System

Operator out of seat with SCV V on. Return to seated position. 

SCC 523944.31

Hydraulic System

Operator out of seat with SCV IV on. Return to seated position. 

SCC 523945.31

Hydraulic System

Operator out of seat with SCV III on. Return to seated position. 

SCC 523946.31

Hydraulic System

Operator out of seat with SCV II on. Return to seated position. 

SCC 523947.31

Hydraulic System

Operator out of seat with SCV I on. Return to seated position. 

SCC 524185.07

Hydraulic System

SCV remote position control system stalled. Increase SCV max flow rate. 


CommandCenter is a trademark of Deere & Company

John Deere is a trademark of Deere & Company

RX32825,000022F-19-20110531