Multiple Displays

PC15323
PC15323-UN-20MAY13

Multiple Displays


Generation 4 CommandCenter™ may be configured to run with the following John Deere displays connected at corner post.

  • Original GreenStar™ Display (without Mobile Processor)
  • GreenStar™ 2 1800 Display
  • GreenStar™ 2 2600 Display
  • GreenStar™ 3 2630 Display

Some applications, such as AutoTrac™, cannot run on both displays at the same time.

Activations do not transfer between displays. Second display must have its own activations to run AMS applications.

Installing a GS2 or GS3 Display

  1. Ensure ignition key and CommandCenter™ are OFF.

  2. Attach display harness to corner post connector and 26-pin display connector to back of display.

  3. Turn ignition key ON.

  4. CommandCenter™ display searches for second display on implement CAN Bus for approximately 60 seconds. If CommandCenter™ was previously in Single Display Mode, it displays a message stating, “Multiple Displays Detected”.

  5. Select a configuration preset:

    Single Display

    • Do NOT use this option in this scenario. This mode is only used if second display is not installed.

    Multiple – Compatibility Mode

    • ISOBUS implements only appear on second display, not on CommandCenter™. Use this option if connected to an ISOBUS implement and desire Auxiliary Reconfigurable Controls to be run from second display.

    Multiple – Implement Viewer

    • ISOBUS implements appear on CommandCenter™ or second display depending on the “Next VT display” setting of implement. NOTE: If ISOBUS implement does not have “Next VT display” function, implement appears on display that starts up first.

    Custom Setup

    • Manually set configurations.

  6. Cycle Ignition Key off and on to save settings.

Removing a GS2 or GS3 Display

  1. Ensure ignition key and CommandCenter™ are OFF.

  2. Detach display harness from 26-pin display connector at back of display.

  3. Turn ignition key ON.

  4. CommandCenter™ display searches for second display on Implement CAN Bus for approximately 2—3 minutes. If CommandCenter™ was previously in one of the Multiple Display Modes, it displays a message stating, “Second Display Not Found”.

  5. Cycle Ignition Key off and on to save settings.

Installing an Original GreenStar™ Display

Original GreenStar™ display can be used for non-guidance functions, such as monitoring a SeedStar 1 planter.

NOTE: Mobile Processor is not compatible and should not be connected.

  1. Ensure ignition key and CommandCenter™ are OFF.

  2. Attach display harness to corner post connector and display connector.

  3. Turn ignition key ON.

  4. Ensure that Tracking is OFF on Original Display. See Original Display manual for instructions.

IMPORTANT: Ensure that tracking has not been turned on since last reprogram or reset of display memory.

To clear display memory, press and hold E, 2, and Clear buttons and reboot. This procedure clears all data stored on display.


CommandCenter is a trademark of Deere & Company

GreenStar is a trademark of Deere & Company

AutoTrac is a trademark of Deere & Company

CZ76372,0000624-19-20140527