Total Rear SCV Flow
-
Check flow setting for each function independently (see implement
operator's manual Specifications section to determine correct motor
flow settings).
Following may cause pump to operate at high pressure:
-
Down pressure systems (drills, air seeders, disks) can be considered
to be zero flow demand after completion of raise or lower cycle (see
Implement Connection Example 1, Pressure Control Valve Applications
(Grain Drills or Air Seeders with Constant Down-Pressure System) in
Hydraulic Connections section).
-
Auxiliary flow control valves (vacuum flow control) - Open implement
flow control valve and adjust tractor flow rate to desired setting
(see Implement Connection Example 4, Planter with Vacuum Motor and
Return Line to SCV Using Motor Return Tip in Hydraulic Connections
section).
-
Cylinder functions where line or orifice restrictions control
flow - Adjust tractor flow control to point where function speed begins
to decrease.
-
Auxiliary control valves (implement stack valves, row guidance)
adjust tractor flow control to lowest setting resulting in correct
operation.
-
Determine total flow demand by adding flow requirements for
each SCV using settings determined in Step 1. Include hitch and power
beyond flow requirements, if applicable (refer to chart for correct
settings).
-
Determine if flow demand exceeds available pump flow (refer
to chart for available pump flow):
-
Flow demand is less than available pump flow but has performance
concern (see your John Deere™ dealer).
-
Flow demand exceeds pump flow:
-
Increase engine RPM if possible.
-
Decrease flow setting on noncritical functions.
-
Convert implement open center valves to closed center operation,
if equipped.
NOTE: Flow measurements made without steering or hitch being
used.
|
SCV FLOW (Approximate)
|
|
Engine rpm
|
Pump Flow (48 cm3 Pump) L/min (gpm)
|
Pump Flow (63 cm3 Pump) L/min (gpm)
|
Pump Flow (85 cm3 Pump) L/min (gpm)
|
|
800
|
42.4 (11.2)
|
52 (13.7)
|
75 (19.8)
|
|
1500
|
85.8 (22.6)
|
109 (28.8)
|
152 (40.2)
|
|
1700
|
98.3 (26)
|
125 (33.0)
|
174 (46.0)
|
|
1900
|
110.7 (29.2)
|
142 (37.5)
|
196 (51.8)
|
|
2100
|
123.1 (32.5)
|
158 (41.7)
|
218 (57.6)
|
|
2200
|
129.3 (34.1)
|
166 (43.9)
|
229 (60.5)
|
|
SCV FLOW OUTPUT (Approximate)1
|
|
SCV Flow Settings
|
L/min (gpm)
|
|
0.12
|
—
|
|
1.0
|
1.9 (0.5)3
|
|
2.0
|
6.1 (1.6)
|
|
3.0
|
13.6 (3.6)
|
|
4.0
|
20.4 (5.4)
|
|
5.0
|
28.0 (7.4)
|
|
6.0
|
40.9 (10.8)
|
|
7.0
|
62.1 (16.4)
|
|
8.0
|
81.4 (21.5)
|
|
9.0
|
107.1 (28.3)
|
|
10.0
|
132 (35)
|
|
Hitch Flow
|
|
Hitch Cylinder
|
Flow
|
|
Diameter (mm)
|
L/min
|
gpm
|
|
90/90
|
71
|
18.7
|
|
100/100
|
88
|
23.2
|
|
100/115
|
102
|
26.9
|
|
1 At 2000 rpm and 454 kg (1000 lbs) of load at
point of use.
2 0.1 = Minimum Flow Setting
3 Observed
under no load.
|
RD47322,000023B-19-20130930
|
|